4. Troubleshooting
•
Check the signal and power with the DVM.
•
If the checked result is normal, replace the motor(
JC31-00123B
).
•
If the checked result is abnormal, check the following.
-
If 24V power is not generated, replace the SMPS board (
JC44-00100D (220V) / JC44-00093D (110V)
).
-
If the control signal is abnormal, replace the main board(
JC92-02742A
).
b) If the motor is operational,
•
Check the Pin Num 8. If the value is abnormal, replace the main board. If the value is normal, replace
the harness.