4. Troubleshooting
•
If the motor operation is stiff, replace the motor(
JC93-00452A
).
ii) Measure the resistance value with DVM.
•
If the measured value is out of the standard area (7~10 ohm), replace the motor(
JC93-00452A
).
b) If the motor is normal, measure the motor signal with DVM.
•
If the phase output voltage is changed in 0~24V(8~10V), the output value is normal.
•
If the phase output voltage is not changed to 0 or 24V, replace the main board(
JC92-02742A
).
► Error Code
A1–4410
► Error message
ACR Shutter Motor Failure: #A1-4410. Turn off then on. Call for service if the problem persists
► Symptom
The ACR shutter operation is abnormal.
► Troubleshooting method
1) Check if there are any foreign substances in the ACR shutter area. If yes, remove them.
2) Check if the ACR shutter harness is connected correctly.
3) If the ACR shutter is in overload status while motor operation, replace the ACR shutter module. If not, check
the drive unit or circuit board.
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-85