Disassembly and Reassembly _ 15
Part
Figure
Description
DUCT-CONDENSER
1. Open the door completely.
5HPRYHWKHWZHOYHVFUHZVKROGLQJWKH
tub front, frame front, and panel control in
place.
Caution
: Before removing the screws,
SODFHDFXVKLRQHGPDWRQWKHÀRRUWR
prevent the handle and frame front from
being scratched, After removing them,
make sure to hold the tub front with your
hand while you are working as the tub may
close and harm you.
Caution
: Do not place the removed screws
on the tub front. They may fall into the sump
assy.
5HPRYHWKHVLQJOHVFUHZKROGLQJWKH
bracket cover fan in place.
3. Remove the cover fan by rotating it
counterclockwise.
Use a jig. If you have no jig, use a tool such
as a pair of long nose pliers. Remove it
carefully so that the part is not damaged.
5HPRYHWKHWZRVFUHZVKROGLQJWKH
cover fan in place.
ఐ
Reassembly is in the reverse order of the removal.