54
4) Separate the Case Sensor from the Case
Brake.
[Caution]
- Be careful not to break the Hook.
5) Separate the Case Sensor and Cover
Sensor.
[Caution]
- Be careful not to break the Hook.
6) Separate the Pole Sensor (2 units) from
the Cover Sensor. Separate the terminal
of the Pole Sensor.
※
Check List
▶
Measure the voltage of Micro S/W ends
: It is normal when the voltage is 0.5V or
below after water supply is completed and
4.5~5.25V after water drain is completed.
▶
Measure the Micro S/W product
: Short when the lever is pulled up and open
when pulled down
Case Sensor Disassembly Part 2
4.
5.
6.
4) Separate the Case Sensor from the Case Brake. [Caution] - Be careful not to
break the Hook. 5) Separate the Case Sensor and Cover Sensor. [Caution] -
Be careful not to break the Hook. 6) Separate the Pole Sensor (2 units) from the
Cover Sensor. Separate the terminal of the Pole Sensor.