Test Modes Part 1
Listen for fan running
Press the Delay Start key to start or stop the fan
motor.
Fan Motor
not working
Fan Motor
t4
After temp increases 2 degrees
F, time is about 50 seconds for
each degree F increase
1. Press the Delay Start key to start or stop the
heater and the circulation pump.
2. If a low water level is sensed, water is
supplied again and the operation continues.
3. The current temperature is shown on the
display.
4. It operates up to 158ºF.
HE error
Circulation
Motor, Heater,
Thermistor
t3
Place some cups on racks and
run circulation pump to verify
water distribution in tub.
1. Press the Delay Start key to start or stop the
pump.
2. If a low water level is detected, water is
supplied again and the operation continues.
Nozzle does
not spray
Circulation
Motor
t2
Water fill in approximately 70
seconds average water pressure,
fills to about 1 inch past heater
shield (very little water showing
in unit)
If you press the Delay Start key, water is
drained for 45 seconds and then the water
supply starts. If the pulse count is more than
660, change the mode. Make sure to change the
mode when the pulse count is more than 660 in
t1 mode.
4E error
9E error
Inlet valve, Flow
Meter, Low
Level Sensor
t1
Test Notes
Activate Mode
Possible
Error
Codes
Related parts