30
1. If you press the Delay Start key, the parts operate just once.
2. There is no stop function.
3. While the Distributor motor is operating, its sensing state is displayed as On/OFF
on the 88 segment display.
4. When the Distributor motor stops, the sensing state (On/OFF) of the micro switch
is displayed.
PE error
Distributor
Motor,
Micro S/W
(only DMR77)
t8
The current temperature is displayed.
No change in water
temperature
Thermistor
t7
1. MICRO SWITCH On
→
The sensing state is displayed as ‘On’ on the 88 segment display.
2. MICRO SWITCH Off
→
The sensing state is displayed as ‘OFF’ on the 88 segment display.
Display error when
turning Micro S/W
on/off
Low Level
Sensor
t6
1. Press the Delay Start key to start the 2 parts.
2. “t5” starts blinking on the display while water is being drained.
3. When draining is finished, “t5” is displayed without blinking.
5E error
Drain Pump,
Low Level
Sensor
t5
Press the Delay Start key to start or stop the fan motor.
Fan Motor not working
Fan Motor
t4
1. Press the Delay Start key to start or stop the heater and the circulation pump.
2. If a low water level is sensed, water is supplied again and the operation continues.
3. The current temperature is shown on the display.
4. It operates up to 70ºC.
HE error
Circulation
Motor, Heater,
Thermistor
t3
1. Press the Delay Start key to start or stop the pump.
2. If a low water level is detected, water is supplied again and the operation continues.
Nozzle does not spray
Circulation
Motor
t2
If you press the Delay Start key, water is drained for 45 seconds and then the water
supply starts.
If the pulse count is more than 660, change the mode.
Make sure to change the mode when the pulse count is more than 660 in t1 mode.
4E error
9E error
Inlet valve, Flow
Meter, Low
Level Sensor
t1
Note
Symptoms (Error)
Related part
Mode
1) Entry method: Press the “Delay Start+Power" Key simultaneously for 3 seconds.
2) Display: “t1” is displayed 3 seconds after everything is displayed.
3) It switches to t1->t2->t3->t4->t5->t6->t7->t8 mode depending on the Normal Key entry
- When operating each mode, the door must be kept closed.
- If an “oE”, “LE” or “tE1” error occur, make sure to enter Service Inspection Mode after resolving it.