29
Generate buzzer sound when the Synchronous Motor is initialized to full load location, and the “FL”
display flashes.
FL
8 times
Display the temperature.
Operate each operating part when the key is pressed. (See the below)
When the ‘Rinse’ Key is pressed, it toggles between cold water On-Off.
When ‘Delicate’ Key is pressed, it toggles between heat On-Off.
When the ‘Half Load’ Key is pressed, it toggles between Synchronous Motor On-Off.
When a different key is pressed during individual operation of the operating part, operating part is
stopped and the applicable operation for the pressed key will start.
Temperature
9 times
Supply water. Drain until low level is detected.
S
7 times
Supply water.
L
6 times
Operate Vent Motor and check whether Rinse is refilled.
dr
5 times
Skip to dr in the Better Model. Operate the Circulation Motor after initializing the Synchronous motor
to Half Load location.
Sn
4 times
Operate Circulation Motor. When the temperature is 60
℃
or above, the heater is turned “off”.
Continuous dispenser operation.
3 times
Operate Circulation Motor.
2 times
Water supply is executed after low level S/W is detected.
If water is not supplied it will display the water supply error.
When low level is detected after water is supplied, the “9E” error will be displayed
1 time
Note
Display
Mode
LINE TEST MODE
¾
TEST mode entry selection button : Heavy + De Power Button
→
After all-LED indication about 2 second, “Micom-Ver.” and “Software-Ver.” will be indicated.
Press the “Normal“ button to test the cycle in order
Line Test Mode