26
PCB TEST MODE
1) Press [Delicate] + [Rinse] + [Power] simultaneously to access this mode
2) All LED’s will illuminate then the EEPROM is tested
- If there is no issue with EEPROM, “EPA” will be displayed. If there is any issue, “Epn” will be displayed.
3) Press the “Normal" Key, to access the test modes
Note: be sure the door is closed
4) Every time you press the “Normal” Key, it changes from P1 -> P2 -> P3 -> P4.
P1 Mode : Operating part test mode. Every time you press the Delay Start Key, it toggles between run and
stop. (Cold water->Circulation Motor->Fan Motor->Drain->Dispenser-> Half Load)
P2 Mode – Not Used
P3 Mode – Not Use
P4 Mode - Touch Key, LED, Display-LED test mode.
Press each button the corresponding LED illuminates after all buttons are pressed all LED’s
illuminate momentarily.
AGING TEST MODE – Continuous Wash Mode
1) Entry method: Press the “SNormal" Key simultaneously when the power is turned on
2) After entering the mode, the display toggles between the total cycle time and total progress time repeatedly
every 1 second.
- To cancel: Turn the power off or press the SNormal keys simultaneously
Test Program Modes