Setting an indoor unit address and installation option

02 series installation option(Detailed)

Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXX

Option SEG1

SEG2

SEG3

SEG4

SEG5

SEG6

Explanation

Page

Mode

-

Use of external room temperature sensor / 

Minimizing fan operation when thermostat 

is off

Use of central 

control

-

Remote 

controller 

display

-

-

-

Indication 

and Details

Indication Details Indication Details Indication Details Indication

Details

Indication Details Indication

Details

Use of 

External room 

temperature 

sensor

Minimizing 

fan operation 

when 

thermostat 

is off

0

2

-

0

Disuse

Disuse

0

Disuse

-

1

Use

Disuse

1

Use

2

Disuse

Use 

*1)

3

Use

Use 

*1)

Option SEG7

SEG8

SEG9

SEG10

SEG11

SEG12

Explanation

Page

-

-

-

EEV opening step when heating stops

-

Remote 

controller 

display

-

-

-

-

-

Indication 

and Details

Indication Details Indication Details Indication Details Indication

Details

Indication

Details

Indication Details

1

-

-

-

0

Default value

-

1

Noise decreasing setting

Option SEG13

SEG14

SEG15

SEG16

SEG17

SEG18

Explanation

Page

Use of external control

Setting the output of external control / 

External heater On/Off signal

S-Plasma ion

Buzzer control

-

Remote 

controller 

display

-

-

Indication 

and Details

Indication Details Indication

Details

Indication

Details

Indication Details Indication

Details

Indication Details

Setting the 

output of 

external 

control

External 

heater On/Off 

signal

2

0

Disuse

0

Thermo on

-

0

Disuse

0

Use buzzer

-

1

ON/OFF 

control

1

Operation ON

-

1

Use

1

Disuse 
buzzer

2

OFF control

2

-

Use 

(

*2)

3

Window ON/

OFF control

3

-

Use 

(

*2)

ENGLISH-26

Содержание AM140RNPDKH Series

Страница 1: ...AM140RNPDKH Air Conditioner installation manual imagine the possibilities Thank you for purchasing this Samsung product...

Страница 2: ...door unit 8 Connecting a refrigerant pipe 9 Cutting or flaring a pipe 10 Leak test and insulation 11 Installing a drain pipe 13 Connecting a drain hose 14 Leak test 14 Wiring work 15 Setting an indoor...

Страница 3: ...all not be responsible for damage originating from unauthorized changes or the improper connection of electric and hydraulic lines Failure to comply with these instructions or to comply with the requi...

Страница 4: ...Manual the cost necessary to reach and repair the unit in safety as required by current regulations in force with slings trucks scaffolding or any other means of elevation won t be considered in warr...

Страница 5: ...ror may occur due to the ballast of the lighting apparatus t Do not install the air conditioner in following places Place where there is mineral oil or arsenic acid Resin parts flame and the accessori...

Страница 6: ...Drill L wrench Measuring tape Tools for trial operation Thermometer Insulation resistance tester Voltage detector Accessories Before installing the product check the following accessories are include...

Страница 7: ...be installed between the indoor unit and outdoor unit 6 The product should be installed on even and sturdy floor 7 The product should not be installed in a humid place such as entrance door or kitche...

Страница 8: ...a hole at a slightly downward slant 15 with a diameter of 60 65 mm Indoor 60 65 mm Outdoor 3 Select the pipe direction and drill a hole on the cover of the indoor unit by knocking the cover with a ha...

Страница 9: ...laring a pipe section f For wall mounted type the pipe can be installed on left right bottom and rear side of the indoor unit Correct tightening torque should be applied depending on the diameter of t...

Страница 10: ...im the rough part with a pipe cutting tool 4 Carry out the flaring work with a flaring tool Flaring tools Clutch type Wing nut type A Die Pipe Yoke Die Pipe Flare nut Pipe diameter D mm Depth of flari...

Страница 11: ...mm Remarks Standard 30 C 85 High humidity 30 C over 85 EPDM NBR Liquid pipe 6 35 9 52 9 t 9 t Heat resistant temperature is 120 C or more 12 70 50 80 13 t 13 t Gas pipe 6 35 13 t 19 t 9 52 25 40 19 t...

Страница 12: ...installing the gas pipe and the liquid pipe allow 10 mm of space between the pipes f When the gas pipe and liquid pipe are attached together use 1 grade thicker insulator Gas pipe 10 mm Liquid pipe 10...

Страница 13: ...is higher than the hole for pipe of the indoor unit 2 When the drain hose installation is completed pour water to check that the water is well drained 3 When passing the pipe through the wall be care...

Страница 14: ...gral type Otherwise water leak may occur from the connection part of the extended hose If it is necessary due to the short length of the hose seal the connection part with silicone sealant Do not use...

Страница 15: ...ower cable to ELCB or MCCB and ELB f Between the power cable and communication cable 50 mm or more space should be maintained Indoor unit 1 Indoor unit 2 Indoor unit 3 Outdoor unit Wired remote contro...

Страница 16: ...ering Nominal dimension for a cable mm2 1 5 2 5 4 Nominal dimension for a screw mm 4 4 4 4 4 B Standard dimension mm 6 6 8 6 6 8 5 9 5 Allowance mm 0 2 0 2 0 2 D Standard dimension mm 3 4 4 2 5 6 Allo...

Страница 17: ...LEC H07RN F 1 Select the capacity of ELB and MCCB by referring to the formula below 5IF DBQBDJUZ PG 9 9 9 J X The capacity of ELB MCCB J 4VN PG SBUFE DVSSFOUT PG FBDI JOEPPS VOJU Rated current Model R...

Страница 18: ...lation 10 10 A Indoor unit10 20 m 10 m 0 m 9 A 1 A 100 m MCCB Indoor unit2 Indoor unit1 ELB f Apply following formula n Coef 35 6 Lk ik 10 of input voltage V 1000 Ak k 1 Calculation t Installing with...

Страница 19: ...ed tube insert a contraction tube CAUTION Unit mm 120 60 20 20 20 180 Power cable 20 Pre installedtubeforthepowercable 3 Insert both sides of core wire of the power cable into the connection sleeve X...

Страница 20: ...k is completed wrap it with the insulation tape to finish Insulation tape t Make sure that the connection parts are not exposed to outside t Be sure to use insulation tape and a contraction tube made...

Страница 21: ...Remove batteries from the remote controller 2 While pressing and holding theTemp andTemp buttons insert the batteries 3 Check if you have entered the option setting stage Step 2 Procedure of option s...

Страница 22: ...utton will be selected in rotation SEG6 SEG8 6 Setting Fan mode Press Mode button to change to FAN mode in the ON status 7 Setting SEG9 SEG10 option Press Low Fan button to enter SEG9 value Press High...

Страница 23: ...n will be selected in rotation SEG21 SEG22 18 Setting Heat mode Press Mode button to change to HEAT mode in the OFF status 19 Setting SEG23 SEG24 mode Press Low Fan button to enter SEG23 value Press H...

Страница 24: ...ess Unit digit of indoor unit address Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details...

Страница 25: ...thermostat is off Central control SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 EEV Step when heating stops SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 2 External control External control output External heater On or O...

Страница 26: ...10 SEG11 SEG12 Explanation Page EEV opening step when heating stops Remote controller display Indication and Details Indication Details Indication Details Indication Details Indication Details Indicat...

Страница 27: ...ff when the external heater is turned on with cooling only indoor unit Cooling only indoor unit To use this option install the Mode Select switch MCM C200 on the outdoor unit and fix it as cool mode G...

Страница 28: ...oling temp Offset When setting SEG3 Standard for mode change Heating Cooling SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 When setting SEG3 Standard for mode change Cooling Heating When setting SEG3 Required ti...

Страница 29: ...2 1 2 1 2 2 3 1 5 3 1 5 3 2 5 4 2 4 2 4 3 5 2 5 5 2 5 5 3 5 6 3 6 3 6 4 7 3 5 7 3 5 7 4 5 Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Explanation PAGE When setting SEG3 Standard for mode change Cooling He...

Страница 30: ...9 4 5 C No delay A 4 5 C 10 minutes B 4 5 C 20 minutes C 6 0 C No delay D 6 0 C 10 minutes E 6 0 C 20 minutes 1 Height difference The difference of the height between the corresponding indoor unit and...

Страница 31: ...ating compensation temp External heater is turned off when the temperature is maintained as 4 5 C 1 C 1 C is the Hysteresis for On Off selection Additional information on SEG 3 4 5 6 8 9 When the SEG...

Страница 32: ...t of an indoor unit address setting option set the SEG3 as A t When changing a digit of indoor unit installation option set the SEG3 as 2 Ex When setting the buzzer control into disuse status Option S...

Страница 33: ...on outdoor temperature sensor E221 2 Error on cond sensor E237 3 Error on discharge sensor E251 Other outdoor unit sensor errors that are not on the above list 1 When there is no communication between...

Страница 34: ...diagnosis errors that are not on the above list EEPROM error E162 EEPROM option error E163 Error due to incompatibility with an indoor unit that special consumption tax is applied E164 If you turn off...

Страница 35: ...ings to make sure indoor unit operates without a problem f Strength of the ground on which indoor unit is installed f Refrigerant gas leak f Power supply status f Insulating capacity of refrigerant pi...

Страница 36: ...DB68 08452A 00...

Отзывы: