EB 7500 EN
9
Operation
Fig. 2:
Indicator with limit contacts
Adjustment screw
Indicator with
proximity switch
Lock
Limit adjuster in
Type 3416
3.2 Adjusting the limit contacts
The listed limit contacts are no longer avail
-
able.
Inductive contacts in Type 3422 Manual
Control Station and Type 3427 Manual
Control Unit
−
Release lock on the front panel and pull
out the indicating unit.
The proximity switches with min. and
max. contacts can be accessed through
the opening on the left-hand side.
−
Use a 2.5 mm hex screwdriver to slightly
loosen the two fastening screws.
−
Move the corresponding proximity switch
until the indicator points to the required
value on the reference scale and a con-
tact is made over the connected switch-
ing amplifier or the LED on the front
lights up when contact is made.
−
Retighten screws and place the marker
on the main scale at the corresponding
place.
Inductive and pneumatic contacts in
Type 3416 Pneumatic Indicator
−
Release lock on the front panel and pull
out the indicating unit.
−
Move adjuster at the side until contact is
made.
Note