F

•  THE USE OF ANY ACCESSORIES OR TOOLING OTHER 

ThAN ThOSE RECOMMENDED IN ThIS MANUAL, MAy 
CAUSE DAMAGE OR INJURE ThE OPERATOR.

 

• 

ThE FLUID CONTAINED IN ThE FLEXIBLE hOSE CAN BE 
vERy DANGEROUS. hANDLE ThE FLEXIBLE hOSE CARE-
FULLy. DO NOT PULL ThE FLEXIBLE hOSE TO MOvE ThE 
EQUIPMENT. NEvER USE A DAMAGED OR A REPAIRED 
FLEXIBLE hOSE.

The high speed of travel of the product in the 

hose can create static electricity through di-

scharges and sparks. It is suggested to earth 

the equipment. The pump is earthed through 

the earth cable of the supply. 

The gun is earthed through the high pressure 

flexible hose.  

All the conductors near the work area must 
be earthed.

•  NEVER SPRAY OVER FLAMMABLE PRODUCTS OR SOL

-

vENTS IN CLOSED PLACES.

•  NEVER USE THE TOOLING IN PRESENCE OF POTENTIALLY 

EXPLOSIvE GAS.

Always check that the product is compatible 
with the materials composing the equipment 

(pump, spray gun, flexible hose and accessories)

 with 

which it can come into contact. Never use paints 
or solvents containing Halogen Hydrocarbons 

(as the Methylene Chloride)

.  If these products come 

into contact with aluminium parts can provoke 
dangerous chemical reactions with risk of 
corrosion and explosion.

Avoid approaching too much to the pump piston 
rod when the pump is working or under pressure. 
A sudden movement of the piston rod can cause 
wounds or finger squashing.

TAKE PROPER SAFETy MEASURES FOR ThE PROTECTION OF 
hEARING IN CASE OF wORK NEAR ThE PLANT.

IF ThE PRODUCT TO BE USED IS TOXIC, AvOID INhALATION 
AND CONTACT By USING PROTECTION GLOvES, GOGGLES 
AND PROPER FACE ShIELDS.

The conditions of guarantee do not apply in the 

following situations:

- improper washing and cleaning of components 

causing malfunction, wear or damage to the 
equipment or any of its parts;

- improper use of the equipment;
- use that does not conform with applicable national 

legislation;

- incorrect or faulty installation;
- modifications, interventions and maintenance that 

have not been authorised by the manufacturer;

- use of non-original spare parts or parts that do 

not correspond to the specific model;

- total or partial non-compliance with the 

instructions provided. 

CONDITIONS OF GUARANTEE

DANGERS

MOVING PARTS OF EQUIPMENT

All moving parts, such as the Group of rising and 
falling pressure plate may cause damage to the 
upper extremities.

• Do  not  approach  with  hands  for  the  moving  parts 

during operation of the equipment.

• During the ascent and descent of the hoist keep hands 

pressing plate and the rim of the container material.

• 

Keep hands away from pump during operation material 

priming piston and compressed air is supplied to the 

unit whenever.

• Before  performing  any  maintenance  or  repair,  di

-

sconnect the compressed air supply and arrange for 
decompression of the pump and of the hoist to the 

rest position (

see diagram F/1 phase A

).

THESE INSTRUCTIONS REFER TO THE CORRECT 
USE OF THE PNEUMATIC RAM. IN ADDITION, READ 
CAREFULLY THE INSTRUCTIONS CONTAINED IN 
THE MANUALS RELEVANTSTO THE DIFFERENT 
COMPONENTS (PNEUMATIC PUMP, DELIVERY 
GUN, ETC.) WHICH CAN BE USED WITH THE RAM.

Содержание LARIUS PNEUMATIC HOIST 200

Страница 1: ...Pneumatic hoist Single mast for 200 litres drums w w w l a r i u s c o m English OPERATING INSTRUCTIONS ED 01 10 2019 Cod 150097...

Страница 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Страница 3: ...ionally FLAT PRESSING EXTRACTION PROCEDURE FROM the STEM for extrusion versions only p 14 REPLACE OF THE DRUM for extrusion versions only p 14 ROUTINE MAINTENANCE p 14 fixing with screw anchors p 15 P...

Страница 4: ...www larius com 4 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 5: ...ment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has no...

Страница 6: ...200 litre drums This system allows for the safe clean transfer of material for use from the storage container directly into the application area This safe reliable system allows empty drums to be repl...

Страница 7: ...rting to cavitate with subsequent defusing They are suitable for pumping highly viscous products The follower plate is equipped with a series of special anti oil rubber high strength flat or toroidal...

Страница 8: ...inlet with bayonet connection Command unit support bracket Up down drive lever Up down pressure regulator Extrusion ram lifting cylinder Available air outlet Pneumatic pump air delivery Open closeval...

Страница 9: ...ations in force in the country where the plant is installed and used Read carefully and entirely the following instructions before using the product Please save these instructions in a safe place The...

Страница 10: ...RTHEPROTECTIONOF HEARING IN CASE OF WORK NEAR THE PLANT IF THE PRODUCT TO BE USED IS TOXIC AVOID INHALATION AND CONTACT BY USING PROTECTION GLOVES GOGGLES AND PROPER FACE SHIELDS The conditions of gua...

Страница 11: ...mustbebetween 3 6 bar NOTE Any other use of the equipment not provided for in the contract of sale is declared improper GROUNDING SETTING UP The operator will have to arrange an environment suitable t...

Страница 12: ...the stem does not present excessive bruising these can cause the pressure plate of the hoist with an automa tically inside the drum Place the drum on the ram s plate Turn the control lever downwards...

Страница 13: ...to the middle position The weight of the equipment will facilitate the descent of the hoist gradually decrease the level of the material In the presence of very dense knob can be left turned down so...

Страница 14: ...e frame proceed as follows Make sure that the regulator K1 air inlet in the stem is at 0 bar and open the stopcock K2 against the regulator it self Turn the knob K4 upward Slowly increase the air pres...

Страница 15: ...ents Holes must be the same size as those in the base plate It is possible to fix the base plate whose existing holes can be used as a guide to drill the floor with precision in a single operation The...

Страница 16: ...l of the pump Decrease the feed air pressure to the pump Manuallyresetthepneumaticmotor see the instruction manual of the pump Disassemble the motor and check see the instruction manual of the pump Ac...

Страница 17: ...he pump Cleanorreplacethewornparts see theinstructionmanualofthepump Clean Disconnect the outlet product pipe Feed pump at mini mumpressureandcheckifdelivery increases the outlet pipe Increase feed ai...

Страница 18: ...9 10 11 12 13 14 15 81010 510429 81083 95158 510003 19186 1 95153 4 6 7 5 8 10 9 Pos Code Description Qty Short terminal Long terminal Handwheel Extrusion ram plate Pneumatic cylinder Guide rod Stirr...

Страница 19: ...14 15 16 17 18 19 91102 35560 22027 4004 900662 91026 91020 91107 3348 96259 Air regulator unit Pos Code Description Qty GPA 1 4 Valve Screw TCE M4x22 M4 Nut Silencer 1 4 Elbow 1 4 hose d10 Elbow 1 4...

Страница 20: ...2 1 1 2 3 4 5 6 7 8 9 10 11 12 12 12 12 11 13 14 15 16 16 17 18 19 20 23 22 21 24 23 22 21 Pos Code Description Qty Flat gaskets blowing Flat disc pressing 3 8 1 4 reduction Drain hose Snap ring int U...

Страница 21: ...www larius com 21 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 22: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: