PNEUMATIC HOIST 200

ED. 01 - 10/2019  - Cod. 150097

D

E

        

TRANSPORT AND  UNPACKING

•  

The packed parts should be handled as indicated in the 
symbols and markings on the outside of the packing.

• 

Before installing the equipment, ensure that the area to 
be used is large enough for such purposes, is properly 
lit and has a clean, smooth floor surface.

•  

The user is responsible for the operations of unloading 
and handling and should use the maximum care so as 
not to damage the individual parts or injure anyone.

 

To perform the unloading operation, use only qualified 
and trained personnel 

(truck and crane operators, etc.)

 

and also suitable hoisting equipment for the weight 
of the installation or its parts. Follow carefully all the 
safety rules. The personnel must be equipped with the 
necessary safety clothing.

•  

The manufacturer will not be responsible for the un-
loading operations and transport to the workplace of 
the machine.

•  

Check the packing is undamaged on receipt of the 
equipment. Unpack the machine and verify if there has 
been any damage due to transportation.

 

In case of damage, call immediately 

LARIUS

  and  the   

Shipping Agent. All the notices about possible damage 
or anomalies must arrive timely within 8 days at least 
from the date of receipt of the plant through Registered 
Letter to the Shipping Agent and to 

LARIUS

.

         

SAFETY RULES

 

The empLoyeR ShALL TRAIn ITS empLoyeeS 

ABoUT ALL ThoSe RISkS STemmIng FRom ACCI-

DenTS, ABoUT The USe oF SAFeTy DevICeS FoR 

TheIR own SAFeTy AnD ABoUT The geneRAL 

RULeS FoR ACCIDenT pRevenTIon In CompLIAn-

Ce wITh InTeRnATIonAL RegULATIonS AnD wITh 

The LAwS oF The CoUnTRy wheRe The pLAnT 

IS USeD.

 

The BehAvIoUR oF The empLoyeeS ShALL 

STRICTLy CompLy wITh The ACCIDenT pReven-

TIon AnD ALSo envIRonmenTAL RegULATIonS 

In FoRCe In The CoUnTRy wheRe The pLAnT IS 

InSTALLeD AnD USeD.

Read carefully and entirely the following 
instructions before using the product. Please
save these instructions in a safe place.

The unauthorised tampering/replacement of 
one or more parts composing the machine, 
the use of accessories, tools, expendable 
materials other than those recommended by 
the Manufacturer can be a danger of accident. 
The Manufacturer will be relieved from tort 
and criminal liability. 

•  KEEP YOUR WORK PLACE CLEAN AND TIDY. DISORDER 

whERE yOU ARE wORKING CREATES A POTENTIAL RISK 
OF ACCIDENTS.

•  ALWAYS KEEP PROPER BALANCE AVOIDING UNUSUAL 

STANCE.

•  BEFORE USING THE TOOL, ENSURE THERE ARE NOT 

DAMAGED PARTS AND ThE MAChINE CAN wORK PRO-
PERLy.

•  ALWAYS FOLLOW THE INSTRUCTIONS ABOUT SAFETY 

AND ThE REGULATIONS IN FORCE. 

• 

KEEP ThOSE whO ARE NOT RESPONSIBLE FOR ThE 
EQUIPMENT OUT OF ThE wORK AREA. 

• 

NEVER

 EXCEED ThE MAXIMUM wORKING PRESSURE 

INDICATED.   

• 

NEVER

 POINT ThE SPRAy GUN AT yOURSELvES OR AT 

OThER PEOPLE. ThE CONTACT wITh ThE CASTING CAN 
CAUSE SERIOUS INJURIES. 

• 

IN CASE OF INJURIES CAUSED By ThE GUN CASTING, 
SEEK IMMEDIATE MEDICAL ADvICE SPECIFyING ThE 
TyPE OF ThE PRODUCT INJECTED. 

NEVER

 UNDERvALUE 

A wOUND CAUSED By ThE INJECTION OF A FLUID. 

• 

ALwAyS DISCONNECT ThE SUPPLy AND RELEASE ThE 
PRESSURE IN ThE CIRCUIT BEFORE PERFORMING ANy 
ChECK OR PART REPLACEMENT OF ThE EQUIPMENT.

•  NEVER MODIFY ANY PART IN THE EQUIPMENT. CHECK 

REGULARLy ThE COMPONENTS OF ThE SySTEM. 

 

REPLACE ThE PARTS DAMAGED OR wORN.

• 

TIGhTEN AND ChECK ALL ThE FITTINGS FOR CONNEC-
TION BETwEEN PUMP, FLEXIBLE hOSE AND SPRAy GUN 
BEFORE USING ThE EQUIPMENT.  

  • 

ALwAyS USE ThE FLEXIBLE hOSE SUPPLIED wITh 
STANDARD KIT. 

The disposal of packaging materials is a customer’s 

competence and must be performed in accordance 

with the regulations in force in the country where 

the plant is installed and used.It is nevertheless 

sound practice to recycle packaging materials in an 

environment-friendly manner as much as possible.

Содержание LARIUS PNEUMATIC HOIST 200

Страница 1: ...Pneumatic hoist Single mast for 200 litres drums w w w l a r i u s c o m English OPERATING INSTRUCTIONS ED 01 10 2019 Cod 150097...

Страница 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Страница 3: ...ionally FLAT PRESSING EXTRACTION PROCEDURE FROM the STEM for extrusion versions only p 14 REPLACE OF THE DRUM for extrusion versions only p 14 ROUTINE MAINTENANCE p 14 fixing with screw anchors p 15 P...

Страница 4: ...www larius com 4 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 5: ...ment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has no...

Страница 6: ...200 litre drums This system allows for the safe clean transfer of material for use from the storage container directly into the application area This safe reliable system allows empty drums to be repl...

Страница 7: ...rting to cavitate with subsequent defusing They are suitable for pumping highly viscous products The follower plate is equipped with a series of special anti oil rubber high strength flat or toroidal...

Страница 8: ...inlet with bayonet connection Command unit support bracket Up down drive lever Up down pressure regulator Extrusion ram lifting cylinder Available air outlet Pneumatic pump air delivery Open closeval...

Страница 9: ...ations in force in the country where the plant is installed and used Read carefully and entirely the following instructions before using the product Please save these instructions in a safe place The...

Страница 10: ...RTHEPROTECTIONOF HEARING IN CASE OF WORK NEAR THE PLANT IF THE PRODUCT TO BE USED IS TOXIC AVOID INHALATION AND CONTACT BY USING PROTECTION GLOVES GOGGLES AND PROPER FACE SHIELDS The conditions of gua...

Страница 11: ...mustbebetween 3 6 bar NOTE Any other use of the equipment not provided for in the contract of sale is declared improper GROUNDING SETTING UP The operator will have to arrange an environment suitable t...

Страница 12: ...the stem does not present excessive bruising these can cause the pressure plate of the hoist with an automa tically inside the drum Place the drum on the ram s plate Turn the control lever downwards...

Страница 13: ...to the middle position The weight of the equipment will facilitate the descent of the hoist gradually decrease the level of the material In the presence of very dense knob can be left turned down so...

Страница 14: ...e frame proceed as follows Make sure that the regulator K1 air inlet in the stem is at 0 bar and open the stopcock K2 against the regulator it self Turn the knob K4 upward Slowly increase the air pres...

Страница 15: ...ents Holes must be the same size as those in the base plate It is possible to fix the base plate whose existing holes can be used as a guide to drill the floor with precision in a single operation The...

Страница 16: ...l of the pump Decrease the feed air pressure to the pump Manuallyresetthepneumaticmotor see the instruction manual of the pump Disassemble the motor and check see the instruction manual of the pump Ac...

Страница 17: ...he pump Cleanorreplacethewornparts see theinstructionmanualofthepump Clean Disconnect the outlet product pipe Feed pump at mini mumpressureandcheckifdelivery increases the outlet pipe Increase feed ai...

Страница 18: ...9 10 11 12 13 14 15 81010 510429 81083 95158 510003 19186 1 95153 4 6 7 5 8 10 9 Pos Code Description Qty Short terminal Long terminal Handwheel Extrusion ram plate Pneumatic cylinder Guide rod Stirr...

Страница 19: ...14 15 16 17 18 19 91102 35560 22027 4004 900662 91026 91020 91107 3348 96259 Air regulator unit Pos Code Description Qty GPA 1 4 Valve Screw TCE M4x22 M4 Nut Silencer 1 4 Elbow 1 4 hose d10 Elbow 1 4...

Страница 20: ...2 1 1 2 3 4 5 6 7 8 9 10 11 12 12 12 12 11 13 14 15 16 16 17 18 19 20 23 22 21 24 23 22 21 Pos Code Description Qty Flat gaskets blowing Flat disc pressing 3 8 1 4 reduction Drain hose Snap ring int U...

Страница 21: ...www larius com 21 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 22: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: