background image

www.larius.com

12

PNEUMATIC HOIST 200

ED. 01 - 10/2019 - Cod. 150097

STOP

UP

DOWN

Check if there are any dents on the drum, they could 
block the shovel plate of the ram inside the drum.

• 

Turn the lifting control lever upwards (

see the illustration

).

• 

Acting on the air governor to the ram, gradually increase the 
feeding pressure to the pneumatic cylinder till the ram starts 
lifting. Let the ram reaches its maximum height.

 

 

 

NOTE

The pneumatic cylinder's speed can be regulated acting on the 
adjustable silencer (

I1

) loceted on the ram control lever (see 

illustration)

• 

Remove the cover from the 200 litres drum to be used.

FLAT PRESSING 
PROCEDURE IN THE CASK

(FOR EXTRUSION VERSIONS ONLY)

• 

Open the primary air supply to the hoist.

• 

Turn the valve knob (

J

1

) upward.

• 

By turning the adjustment knob (

J

2

) to increase gradually the 

supply pressure of the hoist until it starts to rise. (to increase 
the pressure, turn the knob (

J2

) clockwise). 

• 

Let the hoist reaches its highest position.

• 

Remove the cover from the frame by 200 litres that you 

intend to use.

Check all the fittings for connection of 
the various components (pump, hose, gun 
etc.), before using the appliance.

Avoid approaching too much to the hoist 
during lifting and lowering

Check that the stem does not present 
excessive bruising, these can cause the 
pressure plate of the hoist with an automa-
tically inside the drum.

• 

Place the drum on the ram's plate.

• 

Turn the control lever downwards till the shovel plate lowers 

near the upper edge of the drum.

• 

Stop the descent of the ram by turning the control lever to 
the drum correctly so as it is in axis with the shovel plate.

• 

Center the drum correctly so as it is in axis with the shovel 

plate (

when installed

).

• 

Resume the extrusion ram descent, inserting the pump or 

the follower plate (

where installed

), inside the drum.

• 

Open the bleeder valve placed on the shovel plate, (

when 

installed

).

• 

Open the ari passage valve of the shovel plate.

• 

Allow the compressed air flow into the pump acting on the 
air pressure to the minimum valve necessary to a continuous 
working.

• 

The pump will start working and them will stop when all the 
chamber of the product is full. The pump will start working 

again any time the trigger of the gun is pushed or the delivery 
valve is open.

 

In case of difficult suction of the pump, slowly open the 
bleeder valve placed on the shovel plate and close it when 
some product comes out from the vent (

for any possible 

working problem, follow the instructions described in the 
section "problems and solutionsi"

).

Never let pump idle for a long period: it could 
damage the pneumatic motor and ruin the seals.

Fig. 9  - Pneumatic cylinder's speed regulation

J

I1

Содержание LARIUS PNEUMATIC HOIST 200

Страница 1: ...Pneumatic hoist Single mast for 200 litres drums w w w l a r i u s c o m English OPERATING INSTRUCTIONS ED 01 10 2019 Cod 150097...

Страница 2: ...manual without prior notice This manual is to be considered as an English language translation of the original manual in Italian The manufacturer shall bear no responsibility for any damages or inconv...

Страница 3: ...ionally FLAT PRESSING EXTRACTION PROCEDURE FROM the STEM for extrusion versions only p 14 REPLACE OF THE DRUM for extrusion versions only p 14 ROUTINE MAINTENANCE p 14 fixing with screw anchors p 15 P...

Страница 4: ...www larius com 4 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 5: ...ment carry out the decompression procedure explained in this manual and prevent any risk of the equipment starting unexpectedly Report any risk of chemical reaction or explosion if this warning has no...

Страница 6: ...200 litre drums This system allows for the safe clean transfer of material for use from the storage container directly into the application area This safe reliable system allows empty drums to be repl...

Страница 7: ...rting to cavitate with subsequent defusing They are suitable for pumping highly viscous products The follower plate is equipped with a series of special anti oil rubber high strength flat or toroidal...

Страница 8: ...inlet with bayonet connection Command unit support bracket Up down drive lever Up down pressure regulator Extrusion ram lifting cylinder Available air outlet Pneumatic pump air delivery Open closeval...

Страница 9: ...ations in force in the country where the plant is installed and used Read carefully and entirely the following instructions before using the product Please save these instructions in a safe place The...

Страница 10: ...RTHEPROTECTIONOF HEARING IN CASE OF WORK NEAR THE PLANT IF THE PRODUCT TO BE USED IS TOXIC AVOID INHALATION AND CONTACT BY USING PROTECTION GLOVES GOGGLES AND PROPER FACE SHIELDS The conditions of gua...

Страница 11: ...mustbebetween 3 6 bar NOTE Any other use of the equipment not provided for in the contract of sale is declared improper GROUNDING SETTING UP The operator will have to arrange an environment suitable t...

Страница 12: ...the stem does not present excessive bruising these can cause the pressure plate of the hoist with an automa tically inside the drum Place the drum on the ram s plate Turn the control lever downwards...

Страница 13: ...to the middle position The weight of the equipment will facilitate the descent of the hoist gradually decrease the level of the material In the presence of very dense knob can be left turned down so...

Страница 14: ...e frame proceed as follows Make sure that the regulator K1 air inlet in the stem is at 0 bar and open the stopcock K2 against the regulator it self Turn the knob K4 upward Slowly increase the air pres...

Страница 15: ...ents Holes must be the same size as those in the base plate It is possible to fix the base plate whose existing holes can be used as a guide to drill the floor with precision in a single operation The...

Страница 16: ...l of the pump Decrease the feed air pressure to the pump Manuallyresetthepneumaticmotor see the instruction manual of the pump Disassemble the motor and check see the instruction manual of the pump Ac...

Страница 17: ...he pump Cleanorreplacethewornparts see theinstructionmanualofthepump Clean Disconnect the outlet product pipe Feed pump at mini mumpressureandcheckifdelivery increases the outlet pipe Increase feed ai...

Страница 18: ...9 10 11 12 13 14 15 81010 510429 81083 95158 510003 19186 1 95153 4 6 7 5 8 10 9 Pos Code Description Qty Short terminal Long terminal Handwheel Extrusion ram plate Pneumatic cylinder Guide rod Stirr...

Страница 19: ...14 15 16 17 18 19 91102 35560 22027 4004 900662 91026 91020 91107 3348 96259 Air regulator unit Pos Code Description Qty GPA 1 4 Valve Screw TCE M4x22 M4 Nut Silencer 1 4 Elbow 1 4 hose d10 Elbow 1 4...

Страница 20: ...2 1 1 2 3 4 5 6 7 8 9 10 11 12 12 12 12 11 13 14 15 16 16 17 18 19 20 23 22 21 24 23 22 21 Pos Code Description Qty Flat gaskets blowing Flat disc pressing 3 8 1 4 reduction Drain hose Snap ring int U...

Страница 21: ...www larius com 21 PNEUMATIC HOIST 200 ED 01 10 2019 Cod 150097 T h i s p a g e i s i n t e n t i o n a l l y l e f t b l a n k...

Страница 22: ...LARIUS srl Via Antonio Stoppani 21 23801 Calolziocorte LC ITALY TEL 39 0341 621152 Fax 39 0341 621243 larius larius com www larius com...

Отзывы: