The success of a dc to Ac power inverter installation depends mainly on the methods
and materials used for installation. Please read and comply with instructions given
below.
GeneRAl
installation and Wiring compliance
- Installation and wiring must comply with the local and the national electrical codes
and must be done by a certified electrician.
- In building / residential applications, electrical codes do not allow permanent con-
nection of Ac distribution wiring to the inverter’s Ac output receptacles. The recep-
tacles are intended for temporary (as needed) connection of cord connected loads
only. (Model PSE-12275A has a provision for hard wiring to an electrical breaker
panel / load center. read details under “Ac Power distribution and grounding” on
page 10.
- The inverter does not have integral over current protection for the Ac output side
(Except in the case of model PSE-12275A where a 15A breaker is provided if part of
Ac output power is to be fed directly from the front panel of the unit through the
nEMA 5-15r receptacle). Protection should be provided by the installer.
note: Ac power drawn from the neMA5-15 outlet should be limited to 1500W only.
For extracting the full 2750W, hardwiring connection should be used.
- over current protection of the cables from the battery to the inverter has to be
provided by the installer.
- The dc input Positive and negative terminals are isolated from the chassis. Similarly,
the neutral pole of the Ac receptacles / the neutral wire is not bonded to the chas-
sis. System grounding to suit the national / local electrical codes is to be undertaken
by the installer. read details under “Ac Power distribution and grounding”
on page 10.
Preventing electrical Shock
Always connect the grounding connection on the inverter to the appropriate grounding
system. read details under “Ac Power distribution and grounding” on page 10.
installation environment
- The inverter should be installed indoor only in a well ventilated, cool,
dry environment.
- do not expose to moisture, rain, snow or liquids of any type.
- To reduce the risk of overheating and fire, do not obstruct the intake and discharge
openings of the cooling fan.
- To ensure proper ventilation, do not install in a low clearance compartment.
- working with the inverter may produce arcs or sparks. Thus, the inverter should not
be used in areas where there are inflammable materials or gases requiring ignition
protected equipment. These areas may include spaces containing gasoline powered
machinery, fuel tanks, battery compartments.