seCtIOn 9 |
Installation
!
cAUtion!
in these neMA 5-15R receptacles, the current carrying conductor connected to the longer
rectangular slot is isolated from the metal chassis of the inverter. Hence, when the metal
chassis of the inverter is connected to the earth ground, the longer rectangular slot is not
grounded to earth ground. the longer rectangular slot is, therefore, not a “neutral”. Do
not touch this slot as it will be at an elevated voltage with respect to the metal chassis /
earth ground and may produce an electrical shock when touched.
Ac output connections - PSe-12275A
The Ac output connections (n, fig. 7.2) have three insulated conductors – one blAck and
one whITE for carrying current and one grEEn for “equipment grounding”. The grEEn
color “equipment grounding” conductor is connected to the metal chassis of the inverter.
These three conductors exit through a pocket in the front side of the inverter (n, fig 7.2).
These three conductors are used for hard-wiring the inverter to a breaker panel. use the
insulated wire nuts (Marette) / butt splices provided to splice the wires. for drawing the
full 2750w power from the inverter, the output conductors should be hard wired to a suit-
able breaker panel.
A separate plate (p, fig. 7.2) which has a nEMA 5-15r receptacle wired through a 15A
breaker has also been provided. This plate with the receptacle and breaker fits in the
pocket through which the output conductors exit the inverter (n, fig. 7.2). The nEMA5-
15r receptacle can be connected to the three output conductors if the Ac power output
is required to be drawn from the front panel of the inverter. use the insulated wire nuts
(Marette) / butt splices provided to splice the wires. Please note that the neMA 5-15R
receptacle is wired through a 15A breaker and hence, the power delivered from this
receptacle will be limited to 1500 watts only.
!
cAUtion!
the White current carrying conductor is not bonded to the metal chassis of the inverter.
Hence, when the metal chassis of the inverter is connected to the earth ground, this White/
current carrying conductor will not be grounded to earth ground. the white conductor is,
therefore, not a “neutral”. Do not touch this conductor as it will be at an elevated voltage
with respect to the metal chassis / earth ground and may produce electrical shock.
Grounding of PSe-12125A / PSe-12175A to earth or
to other Designated Ground
Please see details regarding grounding under “Ac Power distribution and grounding”
on page 10. for safety, the metal chassis of the inverter is required to be grounded to
the earth ground or to the other designated ground (for example, in a mobile rV, the
metal frame of the rV is normally designated as the negative dc ground). An equip-
ment grounding bolt with a wing nut (j, fig. 7.1) has been provided for grounding the
metal chassis of the inverter to the appropriate ground.