As soon as the Inverter is switched OFF and 120 VAC is removed from the internal Line Side of
the GFCI, Red LED marked “Life End Alarm” (10c in Figs 2.1 and 3.9.1) will flash once and then
will remain OFF. The Green LED (10d in Figs 2.1 and 3.9.1) will switch OFF indicating that AC
power is NOT available at the Load Side outlets.
The Self Monitoring Function inside the GFCI will monitor proper operation of ground fault
protection circuitry every 1 to 10 minutes. If defect in the ground fault protection circuit is
detected, the Red LED marked “Life End Alarm” (10c in Figs 2.1 and 3.9.1) will remain ON and
the GFCI will have to be replaced.
Monthly Testing of GFCI:
Test the operation of the GFCI monthly as follows:
• Switch ON the inverter. As soon as 120 VAC output from the inverter is available on the
internal Line Side of the GFCI, Red LED marked “Life End Alarm” (10c in Figs 2.1 and 3.9.1)
will flash once within 5 sec and then will remain OFF. The Green LED (10d in Figs 2.1 and
3.9.1) will switch ON indicating that AC power is available at the Load Side outlets.
• Plug a test lamp into the outlet and switch ON the test lamp.
• Press the “Test Button” (10a in Figs 2.1 and 3.9.1). The “Reset Button” (10b in Figs 2.1 and
3.9.1) will pop out. The GFCI will be forced to trip and cut off AC power to the load side out-
lets. Green LED (10d in Figs 2.1 and 3.9.1) will switch OFF. The test lamp will also switch OFF.
• Press the “Reset Button” (10b in Figs 2.1 and 3.9.1). The GFCI will reset and AC power to
the load side outlets will be restored. Green LED (10d in Figs 2.1 and 3.9.1) will switch ON.
The test lamp will also switch ON.
• If the above Test / Reset operation cannot be carried out, replace the GFCI.
GFCI Tripping and Reset:
If there is a leakage of 5 to 6mA due to ground fault on the load
side or , there is a Neutral to Ground bond on the load side, the GFCI will trip and the “Reset
Button” (10b in Figs 2.1 and 3.9.1) will pop out. AC power to the load side outlets will be cut
off. Green LED (10d in Figs 2.1 and 3.9.1) will switch OFF. Remove the ground fault in the load
circuit. Press the “Reset Button” (10b in Figs 2.1 and 3.9.1). The GFCI will reset and AC power
to the load side outlets will be restored. Green LED (10d in Figs 2.1 and 3.9.1) will switch ON.
i
INFO
For the Reset Button (
10b in Figs 2.1 and 3.9.1
) to operate, the Inverter has to be in ON
condition so that AC power is available to the internal Line Side of the GFCI.
!
CAUTION!
1. Do not feed the output from the GFCI receptacle to a Panel Board / Load Center where the Neutral
is bonded to the Earth Ground. This will trip the GFCI.
2. If an extension cord is used, please ensure that the cord is 2-Pole Grounding Type (3 pin).
!
ATTENTION!
1. N'alimentent pas la sortie de la prise GFCI à un Panel de sélection / Charger Centre où la
position neutre est lié à la terre. Ce qui déclenche le disjoncteur.
2. Si une rallonge est utilisée, veuillez vous assurer que le cordon est mise à la terre à 2 pôles (3 broches)