102 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 103
SECTION 6 |
Operation, Protections and Troubleshooting
6.5 PROTECTIONS, FAULT MESSAGES AND TROUBLESHOOTING GUIDE
The front panel of the unit has a Red LED marked “FAULT” (13, Fig 2.1). This LED will light
up (steady) when the unit registers any of the
FAULT MODE
situations shown in Table 7.1 of
EVO-RC-PLUS Manual.
Table 7.1 of EVO-RC-PLUS Manual shows details of protections and associated Fault/Error
Messages that will be displayed on the LCD screen of the optional Remote Control EVO-RC-PLUS.
NOTE:
If the optional Remote Control EVO-RC-PLUS is not used, it may be difficult to narrow
down the probable cause of the fault.
6.6 POWERING OFF THE UNIT IN FAULT MODE
If the unit is in “Fault Mode”, it will be possible to power OFF the unit with the ON/OFF Push Button.
(As explained under Section 6.1.2, as long as AC input voltage > 70
±
5 VAC is present, the
unit CANNOT BE POWERED OFF using the ON / OFF Button on the front panel of the unit or
on the optional Remote Control EVO-RC-PLUS. In order to power off using the Power ON/Off
Button, switch OFF the AC input first).
6.7 STANDBY MODE
When the EVO
TM
is in Standby Mode, it will stop inverting or charging / pass through.
i
INFO
Standby Mode may be used to temporary halt normal operation of the Inverter
Charger without switching OFF the unit completely.
For the Standby Mode to be switched ON, the EVO
TM
should be in ON condition and should
be operating in one of the 3 Operating Modes – “Inverting” or “Charging” or “Power Save”
(See Fig 3.1 of the EVO-RC-PLUS Owner’s Manual). When Standby Mode is switched ON, the
EVO
TM
will exit its Operating Mode.
Standby Mode is toggled between ON and OFF conditions as follows:
By momentary pressing (0.1 sec) of ON/OFF Push Button on the front panel of the unit
(11, Fig 2.1)
By momentary pressing (0.1 sec) of ON/OFF Push Key on the optional Remote Control
EVO-RC-PLUS [2, Fig 2.4(a)]
When the EVO
TM
is in “Standby Mode”, operational status will be displayed as follows:
On the front panel of EVO
TM
:
- No LED display. Blue LED marked “ON” (12, Fig 2.1) and Red LED marked “FAULT”
(13, Fig 2.1) will both be OFF.
- No buzzer
Содержание Evolution EVO-1212F
Страница 109: ...SAMLEX AMERICA INC 109 Notes...
Страница 110: ...110 SAMLEX AMERICA INC Notes...
Страница 111: ...SAMLEX AMERICA INC 111 Notes...