24 | SAMLEX AMERICA INC.
SAMLEX AMERICA INC. | 25
SECTION 2 |
Components & Layout
2.
LAYOUT
2.1 LAYOUT OF EVO-1212F AND EVO1224F – FRONT VIEW
1
2
3
4
5
6
8
7
9
10
11
12
13
14
15
Fig 2.1 Layout of Front side EVO-1212F / EVO-1224F
16
LEGEND for Fig 2.1
1. Battery Positive (+) Input Connector (marked "BATTERY POSITIVE"): Stud and Nut, M8 (Pitch 1.25 mm)
• 1a Red Protective Cover for Battery Positive (+) Input Connector – mounted using 2 pcs of M3 (Pitch 0.5 mm) x
10 mm long screws
2. Battery Negative (-) Input Connector (marked "BATTERY NEGATIVE"): Stud and Nut, M8 (Pitch 1.25)
• 2a Black Protective Cover for Battery Negative (-) Input Connector - mounted using 2 pcs of M3 (Pitch 0.5 mm) x
10 mm long screws
3. External Charge Controller Positive (+) Input Connector (marked "+
EXT. charger"): Stud and Thumb Nut, M6
(Pitch 1 mm)
4. External Charge Controller Negative (-) Input Connector (marked "
–
EXT. charger"): Stud and Thumb Nut, M6
(Pitch 1 mm)
5. DC Side Ground Connector (marked " ") – Hole Diameter 6.5 mm for AWG #4 to #6; Set screw M6 (Pitch 0.75 mm)
6. RJ-45 Jack (marked "Battery Temp. Sensor") is used for 2 functions as follows:
a) For input from Temperature Sensor “EVO-BCTS” for temperature compensation when Battery Type 0=Lead Acid
is selected or,
b) For input for contact closure / opening signal from the Battery Management System (BMS) to Pins 4 and 5
(see Pin layout, 19) of the Jack when Battery Type 1= Lithium is selected. When Pins 4 and 5 are shorted due to
contact closure, charging will stop in “Charging” Mode and inverting will stop in “Inverting” Mode
7. RJ-45 Jack (marked "Remote Control") for “EVO-RC Plus” Remote Control
8. RJ-45 Jack (marked "COMM") - for future use.
9. Male AC Power Inlet Plug – Rating 20A (IEC60320 C-20). Will require 20A rated Female Socket
Connector (IEC 60320 C-19). For convenience, the connector has been supplied with the unit
(See Section 2.6 – “Contents of Package”)
10. NEMA5-15R Duplex GFCI Outlets for 120 VAC output [See Section 3.6.1.2 for details].
10a.
Test Button
10c.
Red LED: GFCI Life End Alarm
10b.
GFCI Reset Button
10d.
Green LED: GFCI ON
11. ON/Off Push Button
12. Blue LED “ON”
13. Red LED “Fault”
14. AC output Breaker, 15A
15. AC Input Breaker, 20A
16. Connector (marked "Remote On/Off") for On/Off Control through ex12V signal (9 – 15V, < 10mA):
Screw M2.5; Wire size AWG#30 to AWG#12
•
CAUTION!
Observe correct polarity - Upper terminal is Negative and Lower terminal is Positive
17. Air inlet vents for 2 variable speed, temperature controlled cooling fans.
18. Removable top cover: Fixed with 8 screws – M4 (Pitch 0.7mm) x 4 mm
19. Pin No layout for RJ-45 Jack.
10d
10a
10b
10c
17
18
1a
Red
2a
Black
1 2 3 4 5 6 7 8
19
RJ-45 Jack – Layout of Pins
Содержание Evolution EVO-1212F
Страница 109: ...SAMLEX AMERICA INC 109 Notes...
Страница 110: ...110 SAMLEX AMERICA INC Notes...
Страница 111: ...SAMLEX AMERICA INC 111 Notes...