For the CYCLOMIX
TM
MICRO with CATA flushing :
That mode is only available for the CYCLOMIX
TM
MICRO+ and CYCLOMIX
TM
MICRO+ PH versions. A
J7 shunt inside the electric box is also necessary - (refer to"Annexes" - electric diagram).
The CYCLOMIX
TM
MICRO suggests a BASE
flushing :
Choose :
- to confirm via
:
⇒
the CYCLOMIX
TM
MICRO opens the solvent valve, starts the counting of the BASE
FLUSHING volume and the buzzer sounds continuously.
- Or to select the CATA FLUSHING (BASE side flushing, then CATA side flushing), via
the
or
keys.
⇒
The CYCLOMIX
TM
MICRO suggests the CATA
flushing :
Confirm via
:
⇒
the CYCLOMIX
TM
MICRO opens the BASE solvent valve, starts the counting of the BASE
FLUSHING volume then opens the CATA solvent valve, starts the counting of the CATA FLUSHING
volume and the buzzer sounds continuously.
- Or to select the CATA FLUSHING (CATA side flushing, then BASE side flushing), via the
or
keys.
⇒
The CYCLOMIX
TM
MICRO suggests the CATA
flushing :
Confirm via
:
⇒
the CYCLOMIX
TM
MICRO opens the CATA solvent valve, starts the counting of the CATA
FLUSHING volume, then opens the BASE solvent valve, starts the counting of the BASE FLUSHING
volume and the buzzer sounds continuously.
When you begin to flow, the buzzer sounds intermittently and a breakdown begins on the display unit.
The breakdown display evokes the kind of flushing in progress :
BASE : -F-A 9
or
BASE +
CATA : -F-Ab9
or
CATA +
BASE : -F-bA9
When the breakdown has reached 0, the CYCLOMIX
TM
MICRO closes the solvent valve and the
flushing has ended.
You can stop flushing activating ESC but if so, the CYCLOMIX
TM
MICRO can be
incorrectly flushed.
The volume of flushing with solvent starts when the flowmeter begins counting. It
means that the time between the validation of the flushing and the opening of the
gun is not taken into account.