Doc.-ID: 180731-PT08BAU-SS-Ex Installation Manual rev.00.docx, Page 13 of 24
Fig. 6-4: Opening the ExCam T08-VAx.x.x.x camera
- Carefully pull out the cable and supply flange to the rear and strictly vertical-
ly/perpendicularly (see Figure 6-4). There is a risk of side tilt! Because of negative
pressure it may be difficult to remove the flange.
- The circular cylindrical clearance fit
H8f7
or
H8G7
(in accordance with ISO 286)
of the camera body and flange must not be tilted!
Risk of damage to the flame-
proof gap (DIN EN 60079-1)!
- Caution: Avoid any contact of the screw thread with skin and/or clothes! There is
oil lubricating paste applied, to protect the surface against fretting corrosion and
mechanical stresses.
- Attention: Use particular care when dealing with installed components (camera
module, optics, temperature control, electronics, etc.) which are fixated above the
mounting adapter on the cable and supply flange (cable gland). Risk of damage!
- Attention: When removing the flange, ensure that the Gylon flat gasket (Style
3504, blue) does not get damaged or dirty!
- After the completion of the work at the components which are installed inside the
camera, immediately re-close the housing. Ensure that no foreign objects and par-
ticles are enclosed in the housing!
- For closing the housing, follow the instructions for opening the housing in reversed
order. Please observe the following safety warnings:
Attention!
Insert the flange to reach the end position, in order to ensure ignition
protection and the protection level (IP) of the housing.
Содержание ExCam Series
Страница 1: ...ExCam Series T08 Installation Manual 2018...
Страница 22: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 22 of 24...
Страница 23: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 23 of 24...
Страница 24: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 24 of 24...