background image

 
 
 

 
 
 

Doc.-ID: 180731-PT08BAU-SS-Ex Installation Manual rev.00.docx, Page 15 of 24 

 
6.2.2 

Type T08-TNXCD 

 
 

Attention!  The  pressure-resistant  dome  housing  of  the  type  T08-
TNXCD may only be opened if it is explicitly written in the user manual 
of the respective camera or in the case of manual adjustment, removal 
or changing the SDHC memory card, change of O-ring seals, hardware 
reset, etc. 

 
 

Attention! Observe the warnings given on the type plate: 
Note: Depending on the classification of hazard areas, a work approv-
al  must  be  obtained.  When  adjusting  the  camera,  you  must  prevent 
potentially explosive atmosphere! 

 
 
The T08 ExCam series camera of the type TNXCD may only be opened due to functional 
aspects and only if it is explicitly allowed in the respective user manual. In all other cases, 
the  explosion-proof  housing  may  only  be  opened  and  closed  by  authorized  staff  of 
SAMCON  Prozessleittechnik  GmbH.  Any  damages,  irregularities,  or  changes  which, 
through  the  translucent  polycarbonate  dome  cupola,  are  visible  inside  the  ExCam,  for 
example,  loosened  or not  completely  tightened  components,  discolouration,  or  liquid  in-
clusions (not to be confused with condensed water!),  have to be checked by the manu-
facturer, SAMCON Prozessleittechnik GmbH. 
 
 
Furthermore, please observe the following instructions: 
 

-  Before opening the housing of the T08-TNXCD camera, you should remove the 

external accessories, etc. 
 

-  To open the housing in an appropriate work surrounding, first detach it from the 

wall bracket. 
Attention: Carry the connecting cables along and ensure that they are not dam-
aged or bent (observe the specified bending radius), or disconnect them from the 
Ex e terminal box or Ex e/Ex d plug-and-socket device, etc.! 
 

-  The housing may only be opened via the cable and supply flange. Never open the 

optical lens flange! 

 

-  To open the housing, fix the body first. The cover flange with cable pigtail should 

remain movable (use e.g. clamps or pads on a workbench edge).  
 

Содержание ExCam Series

Страница 1: ...ExCam Series T08 Installation Manual 2018...

Страница 2: ...ea of application 8 5 Transportation and storage 9 6 Commissioning 9 6 1 Installation 9 6 1 1 Types from T08 VA1 1 to VA2 2 10 6 1 2 Type T08 VA2 3 10 6 1 3 Type T08 VA4 3 11 6 1 4 Type T08 TNXCD 11 6...

Страница 3: ...ver flange of type T08 TNXCD 16 Fig 6 7 Position of the O ring seal type T08 TNXCD 17 History of revisions Product T08 ExCam Series Title EX installation instructions for type 08 Doc Id 180731 PT08BAU...

Страница 4: ...d 2 II 2D zone 21 and 22 I M2 1 Explosion protection gas Ex db IIC T6 Gb1 Explosion protection dust Ex tb IIIC T80 C Db IP681 Explosion protection mining Ex db I Mb1 2 1 1 Optional marking If necessar...

Страница 5: ...sed or the effect shall be shown in square brackets For example II 2G Ex db op is op is Ga T4 IIC T6 Gb Note IECEx marking is always an integral part of the identification plate EAC Ex marking and oth...

Страница 6: ...7 11 1 5 6 30 6 25 0 19 4 13 9 8 3 5 6 VA2 2 25 0 18 8 12 5 6 3 34 4 28 1 21 9 15 6 9 4 6 3 VA2 3 28 6 21 4 14 3 7 1 39 3 32 1 25 0 17 9 10 7 7 1 VA3 3 u c u c u c u c u c u c u c u c u c u c VA4 3 x...

Страница 7: ...mbH Attention Prior to installation please consider external sources of heat or cold The permissible temperature range must absolutely be observed Attention If you use the ExCam in the mining sector w...

Страница 8: ...he mining industry and in other hazardous areas with potentially high risk of damage caused by mechanical stresses Attention The ExCam with model T08 TNXCD must not be used for applica tions in the mi...

Страница 9: ...s final assembly and instal lation Avoid extreme heat or cold sources 6 Commissioning 6 1 Installation For the camera s installation and operation the relevant national regulations as well as the gene...

Страница 10: ...ring the camera can be mounted by means of a hinge attachment suitable for every application e g on sight glass fittings in accordance with DIN 28120 28121 or DIN 11851 see Figure 6 1 right Details an...

Страница 11: ...nd for dome cameras of the type T08 VA4 3 Kx PA2 6 1 4 Type T08 TNXCD The PTZ camera of type T08 TNXCD is installed in a hanging position translucent dome facing downwards For this the dome camera can...

Страница 12: ...f housing may only be opened and closed by authorized staff of SAMCON Prozess leittechnik GmbH Any damages irregularities or changes which through the borosili cate sight glass are visible inside the...

Страница 13: ...fretting corrosion and mechanical stresses Attention Use particular care when dealing with installed components camera module optics temperature control electronics etc which are fixated above the mo...

Страница 14: ...in The Gylon gasket must be used in undamaged condition according to the flange hole pattern The surface orientation is arbitrary If when closing the housing you notice that the surface of the fitting...

Страница 15: ...ON Prozessleittechnik GmbH Any damages irregularities or changes which through the translucent polycarbonate dome cupola are visible inside the ExCam for example loosened or not completely tightened c...

Страница 16: ...M8x1 25 threaded holes with screws ring eyelets etc in order to facilitate the screw driving Attention It may be necessary to lay and also rotate cable tails Attention Pull out very carefully and str...

Страница 17: ...ing the flange ensure that the black O ring seal in the groove does not get damaged or dirty Fig 6 7 Position of the O ring seal type T08 TNXCD After the completion of the work at the components insta...

Страница 18: ...n of the equipment must only be carried out by officially qualified and skilled personnel Attention It is absolutely necessary to ground the ExCam series housing via the PA connection 4mm solid rigid...

Страница 19: ...Prozessleittechnik GmbH Damaged pressure resistant housings must be replaced completely If in doubt return the component s to SAMCON Prozessleittechnik GmbH Repair affecting the explosion protection m...

Страница 20: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 20 of 24 11 Certificates 11 1 EU Declaration of Conformity...

Страница 21: ...on Manual rev 00 docx Page 21 of 24 11 2 EU Type Examination Certificate ATEX see http samcon eu 11 3 IECEx Certificate of Conformity see http samcon eu 11 4 EAC Ex Certificate see http samcon eu 11 5...

Страница 22: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 22 of 24...

Страница 23: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 23 of 24...

Страница 24: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 24 of 24...