1
Introduction
The ExCam series (type 08) is an electrical device. It is certified and approved as a pres-
sure-resistant camera system. The cameras may be used in Ex-zones 1, 2, 21 and 22,
including the explosion group IIC (for example, acetylene) and IIIC (conductive and com-
bustible dust). Some models are even approved for the mining industry.
Some models of the T08-
VA… ExCam series can be used, both as stationary and as
mobile explosion-proof camera devices (hand-held use, etc.).
2
Technical data
2.1
Characteristic values for explosion protection
Identification marks
acc. to Directive 2014/34/EU:
II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
I M2
1
Explosion protection (gas):
Ex db IIC T6 Gb
1
Explosion protection (dust):
Ex tb IIIC T80°C Db IP68
1
Explosion protection (mining):
Ex db I Mb
1
2.1.1
Optional marking
If necessary, the mining industry marking (ATEX Group 1) can be omitted. **
The explosion group can be downgraded, if necessary. **
The ambient temperature range can be downgraded, if necessary. **
The temperature class/value (gas or dust) can be downgraded, if necessary. **
Ix
= for models with intrinsically safe circuits [ix] Gx/dx **
op is
= for models with inherent safe opt. radiation [op is Gx/Dx] **
op pr
= for models with protected optical radiation [op pr Gx/dx]. **
Mb
= for models with HF barriers. **
** Please observe the markings on the type plate, the model key, as well as the operating
instructions for the device. In addition, the following warnings are stated on the
identification plate:
1
See optional/additional marking
Содержание ExCam Series
Страница 1: ...ExCam Series T08 Installation Manual 2018...
Страница 22: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 22 of 24...
Страница 23: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 23 of 24...
Страница 24: ...Doc ID 180731 PT08BAU SS Ex Installation Manual rev 00 docx Page 24 of 24...