17
Tel: 886.909 602 109 Email: [email protected]
3.2.2.
Digital Interface
Figure 3-9 Digital Interface
1) SD card slot: Micro SD card can be used in memory space extension of the instrument, or copy of relevant data and documents of
the instrument.
2) LAN (network) interface: a 10/100Mbps network interface, featured by standard 8-pin structure, can be used to select automatically
from two data rates, and also connect to PC via a network cable, related tools and software then can be operated by PC to perform
program control and data transmission to S3101 Cable & Antenna Analyzer.
3) Mini USB interface: used to connect an external PC and then related tools and software can be operated by PC to perform program
control and data transmission to S3101 Cable & Antenna Feeder.
4) USB A-type port: used to connect external USB instrument, such as USB storage device, USB mouse and USB keyboard.
3.2.3.
Test Port
Figure 3-10 Test Port
1) GPS antenna: used to connect GPS antenna instrument and support positioning of the current location of Analyzer.
2) 10MHz I/O port: used to input/output the 10MHz signals, and can also be used to provide 10MHz signal for the Analyzer as
reference signal by connecting with other external instrument; output 10MHz inner signal to external instrument as reference clock.
3) Port 1: test port, with characteristic impedance of 50Ω and N-type female port.
The damage limit level at the test port: +27dBm RF power or ±25V DC voltage, and it may burn down the instrument in case of
exceeding the above range.
3.3.
Screen Area Overview
S3101 is provided with a 7-inch HB TFT true color LED with the function of touch screen and supports soft-key operations of applications
through touch screen. The touch screen display area is as shown in Figure 3-11. Additionally, it provides different settings with different