background image

To  return  to  normal  mode  press  the  TURN  ON  button  shortly  in  either  unit.  Both  units  will 
resume normal operation automatically. After normal operation is resumed the ON led will light 
continuously. 

FIBER OPTIC CONNECTIONS

The probe head unit and the receiver are connected with two fiber optic cables. These are not 
the  same  standard  fiber  cables  as  those  found  in  a  house  installation.  Although  these  cables 
have a 4 layer protection, be mindful that they are not as resilient as copper cables so do not 
bend  them  sharply,  avoid  putting  tension  on  cables  and  do  not  pull  them,  especially  when 
kinks or knots are present. 

Also  do  not  remove  or  bend  the  protective  fiber  optic  cable  boots  since  these  protect  the 
connectors from dust and maintain the necessary alignment for proper accuracy. 

CALIBRATION 

Calibration  is  needed  to  adjust  the  analog  parameters  of  the  fiber  optic  link  and  correct  for 
offsets and temperature drifts in each unit. Every time the CAL button is pressed both probe 
head and receiver run self-test prior to calibration. It is not necessary to disconnect the probe 
from the measured system in order to execute the calibration. 
A short blink from the CAL led indicates that calibration is required. To execute calibration, first 
turn on both units and then shortly press the CAL button. The CAL led will turn on. If for some 

reason both units cannot communicate or the scope is not 50   terminated, the CAL led will 

Ω

BR-XFVP-Rev 6. 12/22

www.saker-mv.com

DO NOT TWIST OR BEND THE FIBER OPTIC CABLE AT SHARP ANGLES. 

MINIMUM 

BENDING RADIUS IS 6 CM

Содержание XFVP10-2

Страница 1: ...User Manual XFVP Medium Voltage Fiber Isolated Voltage Probe Revision 6 BR XFVP Rev 6 12 22 www saker mv com...

Страница 2: ...l accuracy as compared to other optical equipment and saves lots of setup time during research and testing Moreover the XFVP probe can do hot calibrations with no input disconnect which translates int...

Страница 3: ...can be floated at very high voltages please consider all clearances before making any measurements Do not open the probe head or receiver they do not contain user serviceable parts inside Fiber cable...

Страница 4: ...0 65 C Operating temperature receiver 0 70 C ESD EMI standards IEC61000 4 2 61000 4 3 CE certi cation GPSD 2001 95 EC EMC Directive 2014 30 EU RoHS2 2011 65 EU 1 Specs for XFVP20 model 2 3dB small si...

Страница 5: ...mination is needed to provide appropriate high frequency transmission of the signal If the oscilloscope does not have internal 50 termination an optional BNC terminator code XFVPTERM can be supplied I...

Страница 6: ...of IEC EN 61010 031 RECEIVER OSCILLOSCOPE CONNECTION A BNC BNC cable is supplied to connect the receiver to a measuring oscilloscope Use of a good quality cable is recommended as it could affect the m...

Страница 7: ...ead or the receiver press the TURN ON button until the ON Led lights It takes a short press to turn on the units If the probe head fails to turn on check if the batteries are dead and replace them The...

Страница 8: ...emitter It is recommended to use this feature every time the probe is not in use even for shorts periods of time Since the probe head can be set into low power mode remotely from the receiver potenti...

Страница 9: ...boots since these protect the connectors from dust and maintain the necessary alignment for proper accuracy CALIBRATION Calibration is needed to adjust the analog parameters of the fiber optic link a...

Страница 10: ...icator on the measured line that provides visual and clear indication about the presence of potentially dangerous voltages SAKER offers the MVD and MVDZ series of medium voltage presence detectors LOW...

Страница 11: ...n cleaning the exterior Dry the probe before making any voltage measurements The probe is not waterproof The fiber cables should never be disconnected The boots in the cables protect the connectors fr...

Страница 12: ...m verification Bench Multimeter of at least 5 5 digits AC and DC accuracy better than 0 1 Keysight 34450A or similar Adjustable power supply or precision voltage source Banana to BNC cable Pomona 4531...

Страница 13: ...ne batteries in the transmitter Turn on the probe head and receiver press CAL and wait 5 minutes before starting the tests OFFSET Veri cation This test can also be performed with a short at the SMB pr...

Страница 14: ...cking generator and at least 1GHz capability 1 Set the output level of the tracking generator to 5dBm 2 Set the horizontal sweep from 1MHz to 500MHz log sweep 3 Place a jump cable from output of track...

Страница 15: ...tic Emissions IEC EN 55011 A1 2011 Radiated Emissions 30 1000 MHz Class B Electromagnetic Immunity IEC EN 61000 4 2 2010 Electrostatic Discharge 4 kV contact 8 kV air IEC EN 61000 4 3 2007 RF Radiated...

Отзывы: