9
D. Wiring should be long enough to allow the field terminal entry panel to swing down for circuit board
access.
E. Connect the shields ONLY where shown.
F. Check that all wires are tight in their connections.
G. Never use a “megger” to check the wiring.
H. A readily accessible disconnect device (such as breaker, maximum 20A) shall be incorporated in the
field wiring. This disconnect device should be in easy reach of the operator and it must be marked
as the disconnecting device for the equipment.
I.
All conduits should enter the bottom of the enclosure. Do not run conduit through the top or sides of
the enclosure.
2. The following figure shows the wiring diagram of the 6105 integrator.:
Figure 4-1 6105 Integrator Wiring Diagram