For the integrator which is newly put into service or just replaced the battery module, the constant
should be input according to the initial calibration.
·
Power the integrator on
·
Input belt speed (establish test duration in calibration menu, the belt must have been running for over
30 minutes with no load.)
·
Input other constants (zero, span, scale capacity, etc)
4.3
Usual
Usual
Usual
Usual Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
When the material is smoothly delivered but the flowrate indication in integrator varies greatly, there
may be various reasons such as: broken load cell, damaged speed sensor, bad integrator, defective
mechanical construction, signal interference, etc. The former three factors have been mentioned
hereinbefore. The defective mechanical structure on the site mainly contains: inactive trunnion (adjust
the trunnion screw to improve), loose pull bar (fasten the set nut to improve), material blockage (clear
off material to improve). Eliminate any potential problems perceptible. Signal interference is mainly
caused by electromagnetic field. The preventative measures is to route the signal cable separate from
power cable far away, and ensure that the integrator is grounded well (comply with the grounding
specification).