8
removed only fro maintenance procedures with the machine’s power OFF. Be sure to replace all
covers before resuming operation.
4. WARNING
All switches (such as control or power) must be OFF when checking input AC electrical connections,
removing or inserting printed circuit boards, or attaching voltmeters to the system.
5. Incoming voltages must be checked with a voltmeter before being connected to the electronics.
6. WARNING
Extreme caution must be used in testing in, on, or around the electronics, PC boards, or modules.
There are voltages in excess of 115V or 230V in these areas. Avoid high voltage and static
electricity around the printed circuit boards.
7. Maintenance procedures should be performed only by qualified service personnel and in
accordance with procedures / instructions given in this manual.
8. During maintenance, a safety tag (not supplied by Saimo) should be displayed in the ON/OFF
switch area as a precaution instructing others not to operate the unit.
9. Only qualified service technicians should be allowed to open and work in the electronics, power
supply, control, or switch boxes.
10. Objects should never be placed or stored on the integrator.
11. This equipment should not be operated nor utilized in applications other than those stated in the
original order. (To adapt production rates or applications, consult Saimo for recommendations.)
12. All panels covering the electronics must be in place and tight before wash down procedures.
Damage to the electronics could result from water, moisture, or contamination in the electronics
housing.
2.2.3
2.2.3
2.2.3
2.2.3
Wiring
Wiring
Wiring
Wiring (External
(External
(External
(External Power
Power
Power
Power Supply)
Supply)
Supply)
Supply)
Do not connect power unit until you have read and understood this entire section. Improper connection
may result in damage to your integrator.
CAUTION
Verify that the input voltage is correct with an AC voltmeter before you connect it to the integrator.
Earth ground must be provided to the integrator. Do not use conduit to provide this ground.
A readily accessible disconnect device (such as breaker, maximum 20A) shall be incorporated in the
field wiring. This disconnect device should be in easy reach of the operator and it must be marked as
the disconnecting device for the equipment.
1. Critical wiring conditions:
A. Insure power is off.
B. Do not route load cell and signal cables in the same conduit with power cables or any large source of
electrical noise.
C. Earth ground all enclosures and conduits. A ground connection between all conduit is required.