Troubleshooting guide
98-139768-A
Chapter 5: Service & maintenance
5-7
5555
Service & maintenance
RX self test (with SAILOR 6004 Control Panel)
The RX self test runs automatically after start-up. You can also manually start an RX self test.
1. From the idle screen, tap the menu icon in the upper right corner.
2. Tap
Settings
.
3. Tap the menu icon and tap
RX self test
.
4. Tap
Yes
to start the RX self test. The result of the test is shown in the display. If the test
has failed check the antenna installation.
If a printer is connected and enabled the self test results are printed.
Password
entered in
the SAILOR
6004
Control
Panel, but
padlock does
not open
Authorization
failed. Wrong
password or
the
connection to
the SAILOR
6390 Navtex
Receiver is
lost
Check that you enter the correct password.
Check the power supplies, cabling,
Ethernet connection between the SAILOR
6390 Navtex Receiver and the SAILOR
6004 Control Panel. Restart both units:
– SAILOR 6390 Navtex Receiver: remove
and connect power,
– SAILOR 6004 Control Panel: use on/off
button.
Check that no one has logged into the
Service Interface.
Password for Service Interface: sailorsailor
Password for SAILOR 6004 Control Panel:
user
RX self test
failed
Check the antenna installation.
Problem
Symptom
Remedy
Table 5-3: Troubleshooting guide (Continued)