Maintenance
5-2
Chapter 5: Service & maintenance
98-139768-A
5.1.2
Software update
You can update the SAILOR 6390 Navtex Receiver software in the following ways:
•
Software update using the Navtex app
•
Software update with the TMA (ThraneLINK Management Application)
Software update using the Navtex app
System and Navtex app installation
Software update with the TMA (ThraneLINK Management Application)
1. Download the TMA from the Cobham eSupport web site (Self-Service Center, SSC. You
find the SSC in the Service and Support section, 24-7 Service). Make sure to use version
1.04 or higher.
2. Make sure that your PC is on the same network segment as the SAILOR 6390 Navtex
Receiver.
3. Make sure that the SAILOR 6004 Control Panel is switched on.
4. Connect your PC to a free LAN interface of the SAILOR 6390 Navtex Receiver.
5. Start the TMA on your PC. The SAILOR 6390 Navtex Receiver is automatically detected.
Click the icon for the SAILOR 6390 Navtex Receiver. The
Software Download Status
must show
Ready
.
6. The icon
Software update
pulsates yellow when a new software version is detected
for the SAILOR 6390 Navtex Receiver.
The TMA searches all devices connected via USB for new software. You can add an
additional search path. To do so press the icon
Option
s on the software update screen
and select
Search for software
. A dialog box is displayed and you can select a
directory.
7. To start the software update click the icon
Software update
and select
Update.
The
current and the new software version numbers are displayed.
You can also select a specific software version. To do so press the icon
Option
s on the
software update screen and select
Select software
. A list of available software
versions is displayed. Select one and click the button
Update
.
Figure 5-2: LAN connectors of the SAILOR 6390 Navtex Receiver
42.5
mm