RTR-4 Operator’s Manual
System Operation
120300 Rev. D
SAIC Proprietary
4-3
Using the Sum Command
Description
If an image appears too dark after using 99 pulses to acquire it,
you can use the
Sum
command to accumulate more that 99 pulses
per image. The
Sum
command allows the operator to acquire an
initial image then acquire subsequent images that are
automatically added (summed) to the initial image. Follow this
procedure to obtain an X-Ray using the
Sum
command.
Prerequisites
Verify the following prerequisites are completed before beginning
this procedure:
• The RTR-4 is configured in accordance with the applicable
setup procedure in the previous chapter.
• The source and imager units are correctly positioned by the
object to be X-rayed and the source Safety Keyswitch has been
turned 90° clockwise.
• The RTR-4 imaging software has been properly configured and
is initiated and running.
Procedure RTR0005
Obtain a summed X-Ray image as follows:
STEP
ACTION
1
Close all images currently open.
2
Select
Sum
from the
Acquire
menu. The
Fire and
Sum X-Ray Image
dialog box appears.
3
Enter the number of pulses desired up to 99 and
enter the desired time delay up to 300 seconds.
RTR0005a