System Description, Setup, and Quick Start
RTR-4 Operator’s Manual
3-14
SAIC Proprietary
120300 Rev. D
4
Place the controller notebook in the selected area as
far from the imaging area as is appropriate to adhere
to exclusion zone requirements and other safety
regulations.
CAUTION
When unreeling the cable, be sure to grasp the cable
rather than the connector and unreel the cable rather
than let the Imager pull the cable off the reel. This
will extend cable life and reduce the likelihood of
moving the suspect object. Failure to comply may
damage equipment.
5
Connect the green connector of the 50m (164ft)
communications cable to the appropriate connection
on the Imager then unreel and extend the cable to the
controller setup location. Use optional extension
cabling if needed and available.
6
Connect the 30cm (1ft) adapter cable between the
controller and the 50m (164ft) cable reel.
7
If 110/220Vac power is to be used for imager power,
connect the supplied external power adapter directly
to a 110/220Vac outlet and connect the adapter
output to the external power connector on the Imager
control panel.
8
If a power-on time delay is desired, use a small
screwdriver to set the desired delay at the time delay
rotary switch in the Imager battery compartment.
9
Turn on the Imager power switch.
10
Using the key, turn on the X-ray source. Verify that
the X-ray source’s Exposure Selector (display at the
back of the X-ray source handle) is set to 99 pulses.
Do not change this setting during operation of the
RTR-4.
11
If 110/220Vac power is to be used for the controller,
connect the supplied external power adapter directly
to a 110/220Vac outlet and connect the adapter
output to the controller.
12
Turn on the controller.
STEP
ACTION