![Sage 923lts Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/sage/923lts/923lts_user-manual_3443162006.webp)
6
9100-0923-01 V2.0
SAGE INSTRUMENTS
Automated Local Loop Tests
The Sage 923LTS performs tests (individually or as part of a test suite) based on the test
templates supplied by the Sage responder. These local loop test suites may include the
following:
•
Ring voltage and frequency
•
3-Tone Gain Slope
•
C-Measure Noise
•
C-Notch Noise
•
Return Loss
•
3kHz Flat Noise
•
Phase and Amplitude Jitter
•
Impulse Noise and Hits and Droupouts
•
23 Tones
•
Level
•
23 Tone Loss
•
Envelope Delay Distortion
•
Signal-to-Noise
•
Signal-to-Total Distortion
•
Intermodulation Distortion
•
Perceptual Speech Quality Measurement (PSQM)
Other Tests
The 923LTS may come equipped with other tests that do not require an ALTS responder.
They provide detailed results that can be viewed only on the 923LTS (i.e., results are not
collected in the ALTS database). Built-in tests may include:
100 Responder Noise Measurement
The 100 responder noise measurement operates with a type 100 quiet termination test
line.
102 Responder Loss Measurement
The 102 responder loss test operates with the type 100 milliwatt test line.
Perceptual Speech Quality Measurement (PSQM)
The built-in PSQM test operates with a Sage PSQM responder.