![Sage 923lts Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/sage/923lts/923lts_user-manual_3443162021.webp)
SAGE INSTRUMENTS
9100-0923-01 V2.0
21
Test Results N 1
Ü
1:<Test ID>
2:Test Call PASS
3:Call Back PASS
press
q
to view the list of tests
Test Results N 2
ÛÜ
1:23 Tones
2:Jitter PASS
3:Noise PASS
press 2 to view jitter
measurements
Test Call Screen
Select
2:Test Call
to see details about the connection from the 923LTS to the Sage
950RTS responder, including:
•
line voltage and
current
•
number of
milliseconds before
the 923LTS detected
a dial tone
•
number of seconds
before the responder answered the call
Call Back Screen
Select
3:Call Back
to see details about the call from the Sage 950RTS responder to the
923LTS, including:
•
ring voltage
•
ring frequency
NOTE:
The call back option is applicable only if the test included a call initiated by the
950RTS responder in the Central Office
to the 923LTS in the field.
Test Measurement Details
From the Test Results screen, press the
q
key to display a list of tests completed for the
selected call.
Press the number that corresponds to the
desired test to view the measurement data.
For example, press 2 to view jitter
measurements.
23 Tones Measurement Data
The measurement data for each of the 23 Tones tests are grouped into three selections.
Use the keypad to select the desired category.
23 Tones measurements are grouped by:
•
Loss
•
Absolute Delay
•
Noise
Test Call
-50 V 32 mA
DT: 675ms Con: 3.6s
Test Call
line voltage
and current
dial tone delay
connection
time
Содержание 923lts