= Inspect
= Verify
= Perform process
This document and all copies are the property of Spider
®
. All dimensions and data are indicative only.
The user must ensure that the equipment complies with local rules and regulations.
Page 22 of 38
Revision: A
Issue Date: 2017-Dec-18
Document No: 721641-1
7. OPERATING THE HOIST
WARNING
BEFORE operating this hoist, you must understand and follow the instructions in this manual.
You must be properly trained, physically fit and authorized to operate the hoist. Failure to
comply with these instructions could result in serious injury or death.
►
DO NOT OPERATE THE HOIST
IF
you hear unusual noises.
►
DO NOT OPERATE THE HOIST IF
adjustments or repairs seem necessary.
►
DO NOT OPERATE THE HOIST IF
any warning, operating, or capacity instructions are
unclear, missing, illegible, or damaged.
►
DO NOT OPERATE THE HOIST IF
you cannot see the flywheel turning through the
rectangle window on the overspeed.
►
Report any problems to your supervisor and also notify the next operator when changing
shifts. Tag the hoist “
DO NOT USE UNTIL REPAIRED
”.
►
NEVER operate an electric hoist or any electrical equipment in an explosive atmosphere.
Explosive atmospheres exist around refineries, chemical plants, grain elevators, distilleries,
inside silos and mines or around coal handling equipment. This is not a complete list!
Consult an expert if you are in doubt about the safety of your immediate surroundings.
a) n
ormal
o
Peration
- S
tandard
P
endant
Switch the control unit on by turning the
red emergency stop button in the clockwise
direction until it pops out. The
GREEN
Power On Indicator Light on the front of the
electrical box comes on.
For travel in the
UP direction, push in
the
UP operation button.
For travel in the
DOWN direction, push
in the
DOWN operation button.
NOTE: Both buttons are spring-loaded and
will return to the OFF position and apply the
brake when released.
If the hoist does
not immediately stop the platform, press
the emergency stop button AND turn the
overspeed brake ACTIVATION lever in
the LOCK direction. Unplug the power
supply cable. Contact your supervisor.
↑
UP Button
↓
DOWN Button
Emergency Stop
Button
Standard
Pendant