Problem

Possible Cause and Solution

g)  h

oiSt

 

Will

 not r

aiSe

 

l

oad

 

and

 S

oUnder

 

iS

 

a

Udible

 Verify that the hoistway above is clear and that there are no 

overhead obstructions.

 Verify that load is no greater than the rated capacity of hoist 

[5500 lb (2,500 kg)].  Reduce load if necessary.

 Push in the emergency stop button on the pendant and wait 

until the sounder is no longer audible.  Switch the unit on again 

by turning the 

RED

 emergency stop button clockwise until it pops 

out.

Problem

Possible Cause and Solution

h)  h

oiSt

 

doeS

 

not

 S

toP

 

i

mmediately

 

When

 

the

 

UP 

or

 

doWn 

b

Utton

 

iS

 r

eleaSed

 Push the “Emergency Stop button”  on the pendant.

 Call your supervisor.

 Return the hoist to a certified Spider

®

 service center for 

servicing.

Содержание Spider UPPRO P2314

Страница 1: ...The user must ensure that the equipment complies with local rules and regulations Manufactured by Spider 365 Upland Drive Seattle WA 98188 Phone 877 774 3370 Fax 206 575 6240 Email Spider SpiderStagin...

Страница 2: ...perty of Spider All dimensions and data are indicative only The user must ensure that the equipment complies with local rules and regulations Page 2 of 38 Revision B Issue Date 2017 Dec 18 Document No...

Страница 3: ...l and safety features and they must also be capable of carrying out the daily inspections Only authorized persons shall operate this equipment Any operation in violation of these instructions is at th...

Страница 4: ...Spider UpPro P2514 or P2314 Hoist 16 C Specifications of the Spider UpPro P2514 or P2314 Hoist 16 D Parts of the Spider UpPro P2514 or P2314 Hoist 18 E Labels 19 5 PREPARING TO USE THE HOIST A Electri...

Страница 5: ...ument No 721641 1 Revision B Issue Date 2017 Dec 18 Page 5 of 38 Table of Contents Continued 12 TROUBLESHOOTING A No Power to Platform and GREEN Voltage Indicator Light is OFF 32 B Hoist does not Run...

Страница 6: ...ting information prior to using this equipment Call your local hoist supplier for additional information The design and manufacturing of the Spider UpPro P2514 or P2314 complies with UL1323 standards...

Страница 7: ...and practical experience puts him in a position to perform operations safely using the requisite information If the work is performed using SAE see below this person must be appropriately trained in w...

Страница 8: ...tructions and local codes 3 Use the Troubleshooting guide referenced in Section 12 of this manual to solve problems that may develop while using the hoist Repairs must be made only by people trained a...

Страница 9: ...pport system or rigging is complete properly assembled counterweighted or otherwise anchored tied off and not overloaded and ii hoists and platforms are not overloaded c The wire rope is free of defec...

Страница 10: ...ble from Spider 22 Cover the hoist with an insulating material 23 Avoid power lines Make sure the platform or hand tools cannot swing or be blown within a minimum of 10 feet 3 m of an electrical power...

Страница 11: ...y attempt to move the platform up or down could damage equipment or cause injury or death Electrical Hazards Failure of the electrical supply may delay travel of the platform Control system failure ca...

Страница 12: ...MELTED TIP OR BRAZED PORTION OF WIRE ROPE SHOULD NOT EXCEED 380 IN LENGTH NOR DIA OF WIRE ROPE STEEL CENTER WHEN USING IWRC WIRE ROPE CUT BACK THE STEEL CENTER 50 8MM 2 IN TO ALLOW FOR INDEPENDENT MOV...

Страница 13: ...n ANSI A10 4 2 Do NOT expose the wire rope to fire temperatures above 200 f 94 C or passage of electrical current Such exposure will damage the wire rope and make it unsafe 3 Acids will corrode and re...

Страница 14: ...eliminated by making a new attachment This may be done instead of replacing the entire rope Whenever there is abrasion scrubbing flattening or peening that causes loss of more than one third of the o...

Страница 15: ...Reduces service calls Extends electric component life Eliminates power induced down time Allows longer Power Cord drops Spring and Dual Roller Traction Applies constant force to the wire rope Allows 5...

Страница 16: ...s operator to loads greater than the rated working load or an obstruction above Reduces damage to equipment from excess loads Sounder encourages immediate attention to overload situation B Optional Fe...

Страница 17: ...Rope Diameter 9 16 14 mm Wire Rope Specifications 14mm Wire Rope Taurus 6 WS V meets CUL Requirements Zinc plated Right Lay Nominal Resistance 2450 N mm2 Min Breaking Strength 224 25 kN approximately...

Страница 18: ...peed Safety Lock Overspeed Brake Reset Lever Electrical Enclosure Lifting Handle Low Voltage Indicator Light Error Light Brake Release Lever Pendant 2 handed Wire Rope Exit Point Electrical Control Bo...

Страница 19: ...use Use only steel wire rope as speci ed in the Operator s Manual Atenci n Debe leer el Manual de Uso antes de manejar este maquina Solo utilice cable met lico como el especi cado en el Manual de Uso...

Страница 20: ...ect the electrical supply cable based on the hoist s amperage rating which is 16 Amps Use separate but identical electrical cables for each hoist if applicable In applications where two hoists are use...

Страница 21: ...n Wire Rope Push the suspension wire rope through the wire rope inlet of the overspeed safety lock and guide it into the wire rope inlet of the hoist s traction compartment When you cannot push the wi...

Страница 22: ...fy the next operator when changing shifts Tag the hoist DO NOT USE UNTIL REPAIRED NEVER operate an electric hoist or any electrical equipment in an explosive atmosphere Explosive atmospheres exist aro...

Страница 23: ...t of the electrical box comes on For travel in the UP direction push in BOTH the green power button and the UP operation button For travel in the DOWN direction push in BOTH the green power button and...

Страница 24: ...min and all the way in for 60 ft min 18 m min When lifting loads of up to 5500 lb 2500 kg push the UP button halfway in for a lifting speed of 15 ft min 5 m min Push the UP button all the way in for...

Страница 25: ...lowing Wire rope Power supply cable Rigging Platform Hoist Emergency Stop Manual Descent Limit Switch if applicable Verify that all parts are present in proper working order and are not damaged Verify...

Страница 26: ...error light on the front of the electrical box should light up If the hoist keeps running or the error light does not come on the hoist must be repaired To reset the emergency stop button turn the bu...

Страница 27: ...eel turning Flywheel Observation Window De reeve the wire rope Re insert the rope about 12 30 cm into the hoist Holding the wire rope firmly pull it out quickly If the overspeed brake is working corre...

Страница 28: ...Testing the Overspeed Brake ACTIVATION Lever While raising or lowering the hoist activate the overspeed brake by turning the overspeed brake ACTIVATION lever on the overspeed safety lock counterclock...

Страница 29: ...ondary wire rope the secondary wire rope must be removed before the primary wire rope is removed WARNING To prevent platform from tipping and avoid injuries ensure that the platform is properly suppor...

Страница 30: ...18 Document No 721641 1 10 HOIST MAINTENANCE A Regular Maintenance The hoist should be returned to a certified Spider service center for periodic maintenance at least once a year from the date it was...

Страница 31: ...use and equipment is left unattended Store the Spider UpPro P2514 or P2314 Hoist in an indoor facility where the ambient temperature is between 40 F to 158 F 40 C to 70 C and relative humidity does no...

Страница 32: ...n box is off Circuit breaker is tripped Not enough power is being supplied to hoist Plugs are not connected check hoist yoke power cord and power source Damaged electrical cord Power on light is burnt...

Страница 33: ...short power supply cord with larger wires Add a booster transformer at the power source Problem Possible Cause and Solution E Wire Rope will not Reeve Increase hand pressure on the wire rope while pre...

Страница 34: ...ove is clear and that there are no overhead obstructions Verify that load is no greater than the rated capacity of hoist 5500 lb 2 500 kg Reduce load if necessary Push in the emergency stop button on...

Страница 35: ...wheel does not Turn while Hoist moves UP or DOWN and YOU ARE IN THE AIR WARNING DO NOT OPERATE HOIST CALL YOUR SUPERVISOR Turn the overspeed BRAKE ACTIVATION lever on the overspeed clockwise in the LO...

Страница 36: ...PT TO OPERATE THE HOIST MAY CAUSE SERIOUS INJURY OR DEATH Push the emergency stop button Push the overspeed brake test button and wait to be rescued Unplug the hoist from the power cord Call your supe...

Страница 37: ...e rope to reach a safe landing surface You know that the wire rope is not jammed in the hoist You know the reason that the overspeed has been tripped and there will be no danger when it is reset You h...

Страница 38: ...pection Verify all parts of the system are present in proper working order and undamaged 9 9 Wire rope 9 9 Rigging 9 9 Platform 9 9 Power Supply Cable 9 9 Limit Switch es if applicable 9 9 NO damaged...

Отзывы: