= Inspect
= Verify
= Perform process
This document and all copies are the property of Spider
®
. All dimensions and data are indicative only.
The user must ensure that the equipment complies with local rules and regulations.
Page 20 of 38
Revision: A
Issue Date: 2017-Dec-18
Document No: 721641-1
5. PREPARING TO USE THE HOIST
a) e
lectrical
S
UPPly
For trouble-free operation of the Spider
®
UpPro P2514 or P2314 Hoist, the electrical
supply must have sufficient capacity and the circuit breakers must be properly rated. If startup
is sluggish, have a certified electrician determine the voltage at the female end of the electrical
cable coming from the power source. Voltage must be 414-506 VAC.
If the voltage is less than 414 VAC at the hoist connection, do the following:
Install a 3-phase booster transformer at the power source;
Select the electrical supply cable based on the hoist’s amperage rating, which is
16 Amps;
Use separate but identical electrical cables for each hoist; if applicable.
In applications where two hoists are used in tandem, do NOT start both hoists at
the same time to ensure better hoist performance; and,
Maintain a level platform.
b) i
nStalling
h
oiSt
onto
P
latform
Follow the manufacturer’s instructions
for platform assembly.
Lift the hoist into position under power.
NOTE:
The hoist MUST be oriented so that the
suspension wire rope enters the wire rope inlet
on the top of the traction compartment in a
straight line that deviates no more than 2° from
vertical or horizontal.
Attach the hoist stirrup bar to the platform
stirrup using Grade 5 or better bolts OR attach
the hoist using optional hook to hook adapter.
Optional Hook to
Hook Adapter
Hook
Adapter
Connect the hoist to the power supply.
The power indicator light will come on
when the hoist receives power.
Pin View and Side View of 460 V
Hoist Power Supply Connector