LRF 7047- Integrator Manual
914929_TML_LRF7047_en_Version B
Public: 04.2019
Confidential & Proprietary
Safran Vectronix AG – All rights reserved
Page: 35/72
5.5.1 Current Consumption detail: “ Powering Up”
Typical response of the sensor if powered under typical conditions (12 V; T = 25°C; Laboratory power
source)
Figure 22: Typical current peak when powering up (current peak depends on power supply capability)
5.5.2 Current Consumption detail: “ Measurement Sequence”
Typical response of the sensor if powered under typical conditions (12 V; T = 25°C; Laboratory power
source)
Figure 23: Typical current peak during measuring sequence