MULTILUBE
INSTALLATION AND MAINTENANCE
HINS4AEN.doc
24.08.2006 Rev. 4A
2 (18)
Pumping unit models MLP-10-X-XX-XX-XX include 2 pcs supporting blocks:
1. Determine the location of the supporting block with the help of the dimensional drawings.
2. Install the first supporting block in its place with cotter bolts M8x75 or with hexagonal
screws M8 (4 pcs) (Figure 1).
3. Install 2 pcs M8x25 hexagonal screws on the other side of the block.
4. Install the other supporting block on the pumping unit with M8 hexagonal screws.
5. Lift the pumping unit on the M8 hexagonal screws of the supporting block which is already
installed on the wall.
6. Mark the place of the other supporting block (Figure 2).
7. Lift the pumping unit down.
8. Uninstall the block from the pumping unit and install it on the wall with cotter bolts M8x75
or with hexagonal screws M8 (4 pcs) (Figure 3).
9. Lift the pumping unit on the wall on the M8 hexagonal screws.
10. Fasten the pumping unit on the supporting blocks by tightening the M8 hexagonal screws
(8 pcs).
Figure 2.
Marking the place of the other supporting block
Figure 3.
Supporting blocks
installed on a wall
Figure 4.
Pumping unit installed
on the supporting
blocks