![Saeco Minuto Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/saeco/minuto/minuto_service-manual_4047346059.webp)
MINUTO 05 TROUBLESHOOTING
Page / 46
18
Insert a full Water Tank
Insert a full Water Tank
The indication H20 changes from “N” to “Y”.
NOTE: the switching from “N” to “Y” requires about 1-2 seconds.
ERROR: The indication TANK-H2O doesn’t change; check the
capacitive sensor (
fi
xing) and the wiring (JP23)
Insert the BrewUnit
Insert the BrewUnit
The indications BU-P changes from “N” to “Y”.
The indications BU-P changes from “N” to “Y”.
NOTE: removing the BrewUnit the indication from “Y” to “N” requires
NOTE: removing the BrewUnit the indication from “Y” to “N” requires
about 2-3 seconds to switch.
about 2-3 seconds to switch.
ERROR: Check the BU presence Microswitch and the wiring (JP16).
ERROR: Check the BU presence Microswitch and the wiring (JP16).
Close the Door and Dreg Drawer
Close the Door and Dreg Drawer
The indication DOOR change from “N” to “Y”
The indication DOOR change from “N” to “Y”
ERROR: The indication DOOR does not change; check the
ERROR: The indication DOOR does not change; check the
Microswitch for the door and the wiring (JP14). NOTE: without the Dreg
Microswitch for the door and the wiring (JP14). NOTE: without the Dreg
Drawer correctly inserted the DOOR indication cannot
Drawer correctly inserted the DOOR indication cannot
change !
change !
Move Pressure Lever in DRIP position (120V only)
Move Pressure Lever in DRIP position (120V only)
The indications DRIP changes from “N” to “Y”. (120V only)
The indications DRIP changes from “N” to “Y”. (120V only)
Move Pressure Lever in ESPRESSO position (120V only)
Move Pressure Lever in ESPRESSO position (120V only)
The indication ESP change from “N” to “Y”. (120V only)
The indication ESP change from “N” to “Y”. (120V only)
IMPORTANT NOTE: If the Pressure Lever is not inserted (on
IMPORTANT NOTE: If the Pressure Lever is not inserted (on
120V version) a warning message will be shown and the display
120V version) a warning message will be shown and the display
turns to yellow..
turns to yellow..
Check JP4 on interface board.
Check JP4 on interface board.
Press the STAND-BY button
Press the STAND-BY button
The machine passes to the Page 3 (BU PAGE)
Start condition
Start condition
Press STAND_BY “
Press STAND_BY “
” to move to the next screen
” to move to the next screen
Operational check microswitches and sensors
Operational check microswitches and sensors
Содержание Minuto
Страница 3: ...MINUTO CHAPTER 1 INTRODUCTION...
Страница 10: ...MINUTO CHAPTER 2 TECHNICAL SPECIFICATIONS...
Страница 16: ...MINUTO CHAPTER 3 USER INSTRUCTIONS...
Страница 30: ...MINUTO CHAPTER 4 OPERATING LOGIC...
Страница 41: ...MINUTO CHAPTER 5 TROUBLESHOOTING...
Страница 88: ...MINUTO CHAPTER 6 STANDARD CHECKS...
Страница 91: ...MINUTO CHAPTER 7 DISASSEMBLY...
Страница 101: ...MINUTO CHAPTER 8 NOTES...
Страница 102: ...MINUTO 08 NOTES Page 01 01...
Страница 103: ...MINUTO CHAPTER 9 WATER CIRCUIT DIAGRAM...
Страница 107: ...MINUTO CHAPTER 10 ELECTRICAL DIAGRAM...
Страница 108: ...MINUTO 10 WIRING DIAGRAM Page 02 01 Minuto Cappuccino Focus and Class...
Страница 109: ...MINUTO 10 WIRING DIAGRAM Page 02 Minuto Pure 02...