25
FIGURE 23
Install the other key blank in the Left vise jaw use BOTTOM SHOULDER GAUGING. DO NOT use the
machine’s flip up full-function key gauges.
NOW flip up the machine’s full-function key gauges and place them in the wide grooves cut in the keys.
Adjust the key gauges as necessary by loosening the key gauges’s fastening screws. Retighten the screws
when you are finished. See figure 21.
The key gauges now match the spacing of the vise jaws.
You
MUST
verify and readjust, if necessary, the machine’s spacing adjustment. Please refer to SPACING
ADJUSTMENT information.
20.
Cutter Wheel Central Adjustment
This is not required adjustment and should not be necessary during the life of the machine however; if you
replace the machine’s cutter shaft assembly this adjustment will have to be made.
Cutter wheel central position is required when duplicating Medeco high-security keys. If this adjustment is
off you will not be able to cut Medeco keys that work.
Please contact the Factory it this adjustment is necessary.
INSTRUCTIONS:
Precise depth adjustment is required before attempting to adjust the cutter wheel central position.
Use two identical key blanks that you have measured and verified that they both have the same
blade height.
Both vise jaws must be in the standard configuration. Top shoulder gauge both keys, one in each
vise jaw. Remember to leave about 1/32” gap between the key’s bottom shoulder and the left-
edge of the vise jaws.
REMEMBER
to flip down the machine’s built-in full-function key gauges before switching the
machine ON.
Leave the key machine OFF.
Verify that both the stylus and cutter head are in the CENTER- straight UP positions. Cutter head
should be locked.
Содержание RY256