13.
ROTATING THE CUTTER HEAD
(Medeco duplication)
The cutter head must always be rotated in the same direction as the stylus. To rotate the cutter head-Turn
the large black round knob and shaft assembly until you “feel” the shaft “detent” (or loosen) into position.
It does not matter if you turn the large black knob and shaft in the left direction or in the right direction.
You cannot undo the shaft from the machine buy turning it.
Once you have turned the large black knob and shaft assembly to the “detent” (loose position) you may
rotate the cutter head to the angled position of your choice-Left, Right or Center. Grasping the shaft just
below the large black knob and rotating the entire cutter head assembly with your wrist can accomplish
rotating the cutter head. When you are in position you will “feel” the cutter head assembly “fall” into
position. Once the cutter head assembly is in position you may turn the large black knob about 1/ 2 turn to
lock it in place before cutting. It does not matter if you turn the large black knob and shaft 1/ 2- turn in the
left direction or in the right direction. See figure 14.
CENTER CUT POSITION—
Straight UP
LEFT CUT POSITION—
Rotate the cutter head assembly to the RIGHT.
RIGHT CUT POSITION –
Rotate the cutter head assembly to the LEFT.
FIGURE 14