12
RUSH PAR 2 CT Zoom™ User Manual
Do not use an external dimming system to supply power to the fixture, as
this may cause damage to the fixture that is not covered by the product
warranty.
You can hard-wire the fixture to a building electrical installation if you want to
install it permanently. Alternatively, you can install a power plug (not supplied)
that is suitable for the local power outlets on the supplied power cable.
If you install a power plug on the power cable, install a grounding type
(earthed) plug with integral cable grip that is rated minimum 250 V, 6 A.
Follow the plug manufacturer’s instructions and connect the wires in the
power cable as shown in this table:
Earth
,
Ground
or
Neutral
or
N
Live
or
L
US system
Green White
Black
EU system
Yellow/green Blue Brown
The fixture has an auto-ranging power supply that accepts AC mains power
at 100-240 V at 50/60 Hz. Do not apply AC mains power at any other voltage
or frequency to the fixture.
Linking fixtures to power in a chain
If you obtain a 14 AWG / 1.5 mm
2
power input cable and 14 AWG / 1.5 mm
2
throughput cables from Martin™ (see ‘Accessories’ on page 28), you can
relay mains power from one fixture to another by connecting fixtures to
power in a linked daisy-chain, MAINS OUT throughput socket to MAINS IN
input socket.
Using 14 AWG or 1.5 mm
2
cables from Martin™, you can link:
•
Maximum eight (8) RUSH PAR 2 CT Zoom
TM
fixtures in total at 100-120
V, or
•
Maximum eighteen (18) RUSH PAR 2 CT Zoom
TM
fixtures in total at
200-240 V.