background image

24 

RUSH PAR 2 CT Zoom™ User Manual 

Control menus 

To access the control menus, press the MENU button. Use the UP and 
DOWN buttons to navigate the menus. Select any required menu option 
using the ENTER button. For more information, see ‘Using the control 
menus’ on page 15.  

Default fixture settings are shown in 

bold

Menu 

Setting/value Explanation 

DMX Address 

001

–512 

Set fixture’s DMX address 

Dimmer  

Mode 1 

Optically linear 

Mode 2 

Square law 

Mode 3 

Inverse square law 

Mode 4 

S-curve 

DMX State 

Blackout 

Set fixture behavior if DMX signal 
stops: blackout or hold current effect 

Hold 

Backlight 

Off 

Automatically turn off display 
backlight when not in use 

On  

Dimmer Speed 

Fade 

Optimize dimmer for smoothness 

Snap 

Optimize dimmer for speed 

Manual Test 

Warm  

Manually test individual effects 
Set single standalone scene 

Cold   
Zoom 
Dimmer  
Strobe 

Auto Test 

 

Automatic test of all effects 

Temp. 

 

Display fixture’s current temperature 

Fan Mode 

Low 

Adjust cooling fan speed 

Auto 

Fixture time 

 

Display total operation time 

Firmware Version 

 

Display currently installed firmware 
version 

Reset 

 

Force a fixture reset 

 

Содержание PAR 2 CT Zoom

Страница 1: ...PAR 2 CT Zoom User Manual...

Страница 2: ...use of inability to use or reliance on the information contained in this manual The RUSH logo the RUSH name the Martin logo the Martin name and all other trademarks in this document pertaining to ser...

Страница 3: ...rol data link 14 Tips for reliable data transmission 15 Connecting the DMX data link 15 Fixture setup 15 Using the control menus 15 DMX addressing 16 Dimming curves 16 Blackout or Hold if DMX signal s...

Страница 4: ...he beam Do not view the light output with optical instruments or any device that may concentrate the beam This lighting fixture is for professional use only and must be installed by a qualified techni...

Страница 5: ...ure that the fixture is electrically connected to ground earth Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault earth fault p...

Страница 6: ...input and throughput cables that are 16 A rated and temperature rated to suit the application In the USA and Canada the cables must be UL listed type SJT or equivalent In the EU the cables must be ty...

Страница 7: ...y Do not stare directly into the product s light output Do not look at the light output with magnifiers telescopes binoculars or similar optical instruments that may concentrate the light output Ensur...

Страница 8: ...and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all installed accessories Check that all external covers and rigging hardware are securely fasten...

Страница 9: ...ixture 2 Unpack and ensure that there is no transportation damage before using the fixture Never attempt to operate a damaged fixture 3 If the fixture is not going to be hard wired to an AC mains powe...

Страница 10: ...that the surface can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the fixture securely If you install the fixture in a location where it may cause in...

Страница 11: ...The mains power input cable supplied with the fixture is rated 6 A and can supply only one fixture with mains power Do not connect any device to the fixture s MAINS OUT power throughput socket when u...

Страница 12: ...power cable as shown in this table Earth Ground or Neutral or N Live or L US system Green White Black EU system Yellow green Blue Brown The fixture has an auto ranging power supply that accepts AC ma...

Страница 13: ...resent 3 Control buttons MENU Activate the menus or Return to the previous level of the menu structure or Press and hold to exit the menus DOWN Scroll down through a menu UP Scroll up through a menu E...

Страница 14: ...he fixture has 5 pin XLR connectors for DMX data input and output The number of fixtures that you can connect in a daisy chain is limited by the number of DMX channels required by the fixtures in rela...

Страница 15: ...reflect and cause interference If a splitter is used terminate each branch of the link Connecting the DMX data link To connect the fixture to data 1 Connect the DMX data output from the controller to...

Страница 16: ...ol and identical fixture behavior give fixtures the same DMX address To set the fixture s DMX address 1 In the fixture s control panel use the UP and DOWN buttons to select DMX ADDRESS and press ENTER...

Страница 17: ...HOLD the fixture will continue to show the effect that it is displaying at the time 3 Press ENTER to confirm your choice or press MENU to exit without making a change Display panel backlight sleep mod...

Страница 18: ...rm your selection 3 Use the DOWN and UP buttons to change the value 000 255 This will be the equivalent of sending this DMX value to the selected effect 4 Press ENTER to confirm your selection and act...

Страница 19: ...o restore DMX operation exit the MANUAL TEST menu on the control panel Fixture information Fixture temperature readout To check the onboard temperature of the fixture 1 Select TEMP and press ENTER The...

Страница 20: ...ture control White color temperature can be controlled by mixing warm white and cold white LEDs Electronic dimming Overall intensity can be adjusted 0 100 using electronic dimming Shutter effect The e...

Страница 21: ...the fixture Environmental factors that may result in a need for frequent cleaning include Use of smoke or fog machines High airflow rates near air conditioning vents for example Presence of cigarette...

Страница 22: ...to cool for at least 15 minutes 2 Use a large flat bladed screwdriver to unscrew the cap of the fuseholder 3 Replace the fuse with one of the same type and rating only 4 Reinstall the fuseholder cap b...

Страница 23: ...slow fast 132 139 Open 140 181 Pulse fast close slow open 182 189 Open 190 231 Pulse fast open slow close 232 239 Open 240 247 Strobe random 248 255 Open 4 0 255 Warm White 0 100 Fade 255 5 0 255 Cold...

Страница 24: ...erse square law Mode 4 S curve DMX State Blackout Set fixture behavior if DMX signal stops blackout or hold current effect Hold Backlight Off Automatically turn off display backlight when not in use O...

Страница 25: ...MX link fault Damaged step motor or cable connection See next section Contact your RUSH by Martin authorized distributor or service center for assistance Fixture does not respond to DMX control Incorr...

Страница 26: ...riable speed and action random strobe Electronic shutter effect Instant open and blackout Zoom Motorized Control and Programming Control options DMX single standalone scene DMX channels 7 DMX address...

Страница 27: ...cal power consumption 152 W Fuse T 6 3 A Power supply unit Auto ranging electronic switch mode Maximum power and current 120 V 60 Hz 1 25 A 151 W PF 0 993 230 V 50 Hz 0 66 A 148 W PF 0 961 Measurement...

Страница 28: ...m 7 4 ft P N 11541510 Power relay cable 14 AWG SJT 1 5 mm2 H05VV F with PowerCon connectors 3 25 m 10 7 ft P N 11541511 Power connectors Neutrik PowerCon NAC3FCA power input connector cable mount blu...

Страница 29: ...is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of RUSH by Martin products Photobiological Safety Warning The label shown below is displayed o...

Страница 30: ......

Страница 31: ......

Отзывы: