6 – AC mains power IN
A blue Neutrik PowerCon socket is provided to connect the fixture to AC
mains power.
7 – AC mains power OUT (THRU)
See ‘Safety information’ on page 4. The light-grey Neutrik PowerCon socket
can be used to supply power to other fixtures only if the supplied power input
cable is replaced as directed in this manual and safety limits are respected.
Control data link
A DMX 512 data link is required in order to control the fixture via DMX. The
fixture has 5-pin XLR connectors for DMX data input and output.
The number of fixtures that you can connect in a daisy chain is limited by the
number of DMX channels required by the fixtures in relation to the maximum
512 channels available in one DMX universe. No matter how many channels
are available, we recommend connecting a maximum of 32 fixtures in one
daisy chain.
Note that if independent control of a fixture is required, it must have its own
DMX channels. Fixtures that are required to behave identically can share the
same DMX address and channels. To add more fixtures or groups of fixtures
when the above limit is reached, add a DMX universe and another daisy-
chained link.