MODEL 53515/53615/63515/63615/73515/73615
45
1. All indictors
display on front
panel.
A. Wiring of display board with
control board fails to work.
B. Control board is faulty.
C. Transformer is damaged.
D. Electrical service is not
stable.
E. Display board is faulty.
A. Check and replace the
wiring.
B. Replace control board.
C. Check and replace
transformer.
D.
Check
and
adjust
electrical service.
E. Replace display board.
2. No display on
front panel.
A. Wiring of display board with
control board fails to work.
B. Display board is damaged.
C. Control board is damaged.
D. Adapter is damaged.
A.
Check
and
replace
wiring.
B. Replace display board.
C. Replace control board.
D. Replace adapter.
3. E1 Flashes
A. Wiring of locating board with
control board fails to work.
B. Locating board damaged.
C. Mechanical driven failure.
D. Faulty control board.
E. Wiring of motor with control
board is fault.
F. Motor is damaged.
A. Replace wiring.
B. Replace locating board.
C.
Check
and
repair
mechanical part.
D. Replace control board.
E. Replace wiring.
F. Replace motor.
4. E2 Flashes
A. Wiring of locating board with
control board fails to work.
B. Locating board is damaged.
C. Control board is damaged.
A. Replace wiring.
B. Replace locating board.
C. Replace control board.
5. E12 or E22
Flashes
A. Hall component on locating
board is damaged.
B. Wiring of locating board with
controller fails to work.
C. Control board is damaged.
A. Replace locating board.
B. Replace wiring.
C. Replace control board.
6.
E3
or
E4
Flashes
A. Control board is faulty.
A. Replace control board.
Содержание 53515
Страница 12: ...MODEL 53515 53615 63515 63615 73515 73615 8 Remark Remove the flow meter from 63615 it will be 63515...
Страница 52: ...MODEL 53515 53615 63515 63615 73515 73615 48 Construction figure of 63615...