MODEL 53515/53615/63515/63615/73515/73615
16
setting are success and return program display mode
E.
Manual/Return button
Press
in any status, it can proceed to next step. (Example: Press
in Service status, it will start regeneration cycles instantly if the
outlet water is unqualified; Press
while it is in Backwash status, it
will end backwash and go to Brine at once.)
Press
in program display mode, and it will return to Service; Press
in program set mode, and it will return program display mode.
Press
while adjusting the value, then it will return program display
mode directly without saving value.
F. Down ▼ and Up ▲
In program display mode, press ▲or ▼ to view all values.
In progra
m set mode, press ▲ or ▼ to adjust values.
Press and hold both ▲and ▼for 5 seconds to unlock the buttons.
2.2. Basic Setting & Usage
A. Parameter specification
Function
Indicat
or
Factory
Default
Parameter Set
Range
Instruction
Time of
Day
Random 00:00
~
23:59
Set the time of day when use: “:” flashes
Control
Mode
A-01
A-01
A-01
Meter Delayed: Regenerate on the day
although the available volume of treated
water drops to zero (0). Regeneration
starts at the regeneration time.
A-02
Meter Immediate: Regenerate
immediately when the available volume
of treated water drops to zero (0).
A-03
Intelligent Meter Delayed: Meter
Delayed Regeneration type, but by
setting Resin Volume, Feed Water
Содержание 53515