MODEL 53515/53615/63515/63615/73515/73615
6
A-03
Intelligent
Meter
Delayed
Meter Delayed Regeneration type, but by setting Resin
Volume, Feed Water Hardness, Regeneration Factor, the
controller will calculate the System Capacity. Regeneration
mode is the same as A-01.
A-04
Intelligent
Meter
Immediate
Meter Immediately Regeneration Type, but by setting Resin
Volume, Feed Water Hardness, Regeneration Factor, the
controller will calculate the System Capacity. Regeneration
mode is the same as A-02.
Maximum interval regeneration days (Suit for 63615/73615)
Under the situation of service reaching the setting days and the
volume not yet, it could enter into regeneration process or fast rinse
forcibly when current time is the same as regeneration time.
1.3. Service Condition
Runxin valve should be used under the below conditions:
Items
Requirement
Working
conditions
Water
pressure
0.2MPa
~
0.6MPa
Water
temperature
5
℃~
50
℃
Working
environment
Environment
temperature
5
℃~
50
℃
Relative
humidity
≤95%
(
25
℃)
Electrical
facility
AC100
~
240V/50
~
60Hz
Inlet water
quality
Water
turbidity
Filter (53515/53615)
<
20FTU
Down-flow regeneration softener (63515/63615)
<
5FTU
Up-flow regeneration softener (73515/73615)
<
2FTU
Water
hardness
First Grade Na
+
<
6.5mmol/L
;
Second Grade Na
+
<
10mmol/L
Free chlorine
<
0.1mg/L
Iron
2+
<
0.3mg/L
CODMn
<
2mg/L
(
O
2
)