10
Preparing for Installation
Preconfiguring the Access Point (Standalone Only)
Step 2: Supply DC Power to the CMAP
In this step, you connect the CMAP to the administrative computer, and then you power
it on using 12 VDC power.
The customer provides a separate 2A 12 VDC power supply (
) from a local or online
electronics supply store. The power supply, which is designed to be used by a CCTV or
similar application, includes a 2.5mm inner-diameter, 5.5mm outer-diameter center plug.
Figure 6.
Typical CMAP customer-supplied DC power supply
Contact your authorized Ruckus Wireless reseller for a reset pushbutton assembly for the
CMAP, similar to the one shown in
Figure 7.
Typical CMAP reset pushbutton assembly, part number 902-0103-0000
Use the following to connect the CMAP to the administrative computer and then power
it on using 12 VDC power.
1.
Connect one end of an Ethernet cable to the Ethernet port on the CMAP, and then
connect the other end to the administrative computer’s Ethernet port.
2.
Remove the protective cap from the DC connector on the CMAP.
3.
Connect the power adapter assembly to the DC connector on the CMAP.
4.
Connect the DC power supply to the barrel of the power adapter assembly.
5.
Connect the DC power into an AC power outlet.
The CMAP is now powered by DC, and you can press the reset button on the power
adapter assembly to reboot the CMAP.