background image

PROPRIETARY NOTICE

The product information and design disclosed herein were originated by and are 
the property of Telex Communications, Inc. Telex reserves all patent, proprietary 
design, manufacturing, reproduction, use and sales rights thereto, and to any 
article disclosed therein, except to the extent rights are expressly granted to 
others.

COPYRIGHT NOTICE

Copyright 2006 by Telex Communications, Inc. All rights reserved. 
Reproduction, in whole or in part, without prior written permission from Telex is 
prohibited.

WARRANTY NOTICE

See the enclosed warranty card for further details.

UNPACKING AND INSPECTION

Immediately upon receipt of the equipment, inspect the shipping container and 
the contents carefully for any discrepancies or damage. Should there be any 
discrepancies, notify factory service immediately. Notify the freight company and 
factory service of any shipping damage.

CUSTOMER SUPPORT

Technical questions should be directed to:

Customer Service Department
Telex Communications, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A.
Telephone: (800) 392-3497
Fax: (800) 323-0498
Factory Service: (800) 553-5992 (Lincoln, NE)

RETURN SHIPPING INSTRUCTIONS

Customer Service Department
Telex Communications, Inc.
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A.
Telephone: (800) 392-3497
Fax: (800) 323-0498
Factory Service: (800) 553-5992 (Lincoln, NE)

Please include a note in the box which supplies the company name, address, 
phone number, contact person regarding the repair, the type and quantity of 
equipment, a description of the problem and the serial number(s)

SHIPPING TO THE MANUFACTURER

All shipments of product should be made via UPS Ground, prepaid (you may 
request a different shipping method from Factory Service). Any shipment 
upgrades will be paid by the customer. The equipment should be shipped in the 
original packing carton. If the original carton is not available, use any suitable 
container that is rigid and of adequate size. If a substitute container is used, the 
equipment should be wrapped in paper and surrounded by 4 (four) inches of 
excelsior or similar shock absorbing material. All shipments must be sent to the 
following address and must include the Proof of Purchase for warranty repair. 
Upon completion of any repair, the equipment will be returned via United Parcel 
Service or specified shipper, collect.

Factory Service Department
Telex Communications, Inc.
8601 Cornhusker Hwy.
Lincoln, NE 68507 U.S.A.
Attn: Service

This package should include:

Components

Description

Qty

90107772000

RVON-I/O Final Assembly

1

38110387

RTS Warranty Card

1

93507772000

RVON-I/O User Manual

1

8800102668

A/C Cord/ Conn 18 GA SVT 
(7ft) Belden #17250, Kent

1

Содержание RVON-I

Страница 1: ...RVON I O User Manual 9350 7772 000 Rev E 6 2006...

Страница 2: ...nd Avenue South Burnsville MN 55337 U S A Telephone 800 392 3497 Fax 800 323 0498 Factory Service 800 553 5992 Lincoln NE Please include a note in the box which supplies the company name address phone...

Страница 3: ...rs and Connections 16 Configuration 17 Setup IP Addresses 17 Configure the IP Address from a KP 32 KP 632 or a KP 832 17 Configure the IP Address from a KP 812 18 Configure the IP Address Using Telnet...

Страница 4: ......

Страница 5: ...OIP Virtual Keypanel McCurdy 9500 to RVON I O to RVON 1 RVON 8 RVON I O or VOIP Virtual Keypanel RVON I O is fully compatible with the following internationally recognized standards and protocols G 71...

Страница 6: ...nnected channel 1 VOIP connected Channel 1 2 VOIP not connected channel 2 VOIP connected Channel 2 3 VOIP not connected channel 3 VOIP connected Channel 3 4 VOIP not connected channel 4 VOIP connected...

Страница 7: ...s Signal Type Fully differential balanced Nominal Level 8dBu Maximum Level 20dBu Input Impedance High 22K Output Impendance Low 600 A D and D A Specifications Sampling Rate 8 KHz Resolution 8 bits Con...

Страница 8: ...Audio OUT 8 RVON I O Audio OUT 9 N A See page Figure 2 DB 9 Crossover Cable Connection Diagram on page 6 DB 9 Function Serial Port 1 N A 2 RXD RVON I O Received Data 3 TXD RVON I O Transmitted Data 4...

Страница 9: ...The Pass through Port is used to send serial port data over Ethernet The Serial Debug Shell provides the user access to a command shell this is similar to Telnet except the connection is made through...

Страница 10: ...sover Cable Connection Diagram 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 DB 9 Crossover Cable Connection Diagram Optional On the ADAM CS and the Zeus connect pins 3 6 and 9 to sheild 1 2 3 4 5 6 1 2 3 4 5 6...

Страница 11: ...ON 8 The KP 32 RVON I O is in LOCAL mode When operating in REMOTE mode a digital keypanel such as KP 32 with RVON 1 is connected via Ethernet to an RVON I O which is then connected to an intercom Syst...

Страница 12: ...ge 8 To reset the IP Address to default on the RVON I O do the following 1 On the front of the RVON I O unit push and hold buttons 1 and 2 then push the RESET button Hold the buttons in for 15 seconds...

Страница 13: ...chan dest_codec optional 7 Once you are finished configuring the RVON I O type ACTIVATE into the command prompt to activate the configuration setup on the RVON I O Basic Remote Mode Setup In Remote Mo...

Страница 14: ...Connect the Matrix to the RVON I O via I O ports using a DB 9 crossover cable See page 6 for the different connection diagrams 4 Connect the RVON I O to Ethernet 5 Set the IP Address for the RVON I O...

Страница 15: ...rate of the device it is connecting with 5 Using Telnet or Serial programming configure the RVON I O as follows set serial mode ip_addr baud NOTE To see actual Telnet commands see RVON I O Command Ta...

Страница 16: ...WAN Reset Power 1 8 16 24 RTS RVON I O Call waiting Mic Headset Vol MENU FWD BACK MUTE CLR PGM NUM SLIST 1 PL IFB 2 AUTO ISO 3 PHONE RELAY 4 PREFIX TYPE 5 6 COPY CW EX COPY 7 E PNL DISPLAY 8 9 MULT F...

Страница 17: ...Reset Power 1 8 16 24 RTS RVON I O Call waiting Mic Headset Vol MENU FWD BACK MUTE CLR PGM NUM SLIST 1 PL IFB 2 AUTO ISO 3 PHONE RELAY 4 PREFIX TYPE 5 6 COPY CW EX COPY 7 E PNL DISPLAY 8 9 MULT FUNC...

Страница 18: ...ice versa The same holds true for the upper portion of the graphic where the audio coming from the RVON I O going towards the Zeus is converted to analog LAN WAN Reset Power 1 8 16 24 RTS RVON I O Cal...

Страница 19: ...configure one as Remote and the other as Local However remote to remote setup is the preferred system setup for trunking LAN Reset Power 1 8 16 24 RTS RVON I O Reset Power 1 8 16 24 RTS RVON I O POWE...

Страница 20: ...3 J1 is configured for RS232 J21 must be jumped from pins 1 to 2 to select UART B for RS485 RVON 1 keypanel operation J2 Connector The RVON 1 card is designed to be used with either a keypanel or an R...

Страница 21: ...o make sure DIP switch 2 is in the CLOSED position configuration via IO port 8 enabled To configure the IP Address from a KP 32 KP 632 KP 832 keypanel do the following 1 Connect the RVON I O using ser...

Страница 22: ...ppears NOTE Once you have entered the Netmask you may need to enter the Gateway IP Address A Gateway is a node for example a computer on a network that serves as an entrance to another network 17 Pres...

Страница 23: ...the second octet NOTE Tap the Select knob to skip over any octet that does not need modifications 15 Repeat steps 13 and 14 until the entire Netmask is entered 16 Tap the Select knob The Gateway IP A...

Страница 24: ...e following 1 Open a Command Prompt application session 2 At the prompt type TELNET IP Address The IP Address is the existing IP Address assigned to the RVON I O 3 Press Enter The RVON login screen ap...

Страница 25: ...ing the Serial Debug Port NOTE In order to use the Serial Debug Port to set the IP Address for your RVON I O you must know the intended IP Address Also you must make sure DIP switch 2 is not enabled C...

Страница 26: ...RVON I O at SERIAL Ethernet Telnet Only Setup Serial Port 38 4000 baud 8 data bits 1 stop bit No Parity NO Flow control Telnet IP Address port 23 Configure RVON I O Using Telnet and Serial Port IMPOR...

Страница 27: ...ess is the IP Address assigned to the RVON I O 3 Press Enter The RVON login screen appears 4 In the login field type the RVON login default telex 5 Press Enter 6 In the password field type the RVON pa...

Страница 28: ...Configuration 24 8 At the prompt type dbgcmd to access the debug command screens 9 Press Enter An MXP prompt appears Figure 8...

Страница 29: ...et the VAD threshold silence detection Adaptive refers to autoselect The can be 20 to 10 dBm set channel chan Help screen which lists all set chan commands 0 7 This refers to VOIP channel setting set...

Страница 30: ...rate to use 50 through 115000 set gpio Help screen which lists all set gpio commands set gpio mode X Set the gpio mode 0 Pass Through 1 1 Keypanel 2 All Keypanels set gpio ip_addr X X X X Set the dest...

Страница 31: ...Packet Packets Second Encoded Audio bytes IP Overhead bytes Total Packet Size bytes Bandwidth Bytes sec Bandwidth kbps side Bandwidth kbps channel 0 3 6 9 G 711 64k 10 100 00 80 60 140 14000 112 224 1...

Страница 32: ...0 Y 16 729AB 8k 10 N 17 729AB 8k 20 N 18 729AB 8k 40 N 19 729AB 8k 60 N 20 723 5 3k 30 Y 21 723 5 3k 60 Y 22 723 5 3k 30 N 23 723 5 3k 60 N 24 723 6 3k 30 Y 25 723 6 3k 60 Y 26 723 6 3k 30 N 27 723 6...

Страница 33: ...Single Port Mode In 1 Keypanel mode also referred to as single port mode all GPI O on the RVON I O are associated with only one keypanel Associating the GPI O with a keypanel allows you to access add...

Страница 34: ...t you need to communicate with the specified address EXAMPLE 2 RVON I O units are connected to the same Zeus System RVON I O A and RVON I O B RVON I O A is connected to Zeus ports 1 and 2 on RVON I O...

Страница 35: ...This must be changed to a non zero number NOTE Make sure to set the panel poll ID to 0 when trunking in Remote Mode Doing this will ensure the RVON I O will not respond to polls as a keypanel If the...

Страница 36: ...Configuration 32...

Страница 37: ...tings done in AZedit RVON 8 IP Address should be set to 192 168 0 10 Running version 1 2 0 firmware or higher To set the channel information do the following 1 Connect a keypanel to the J1 I O 1 Ether...

Страница 38: ...RVON I O for a Remote Keypanel NOTE In this example the first port of Zeus J1 is connected to the I O connector of the RVON I O then connected via Ethernet back to the first channel of an RVON 1 card...

Страница 39: ...RVON I O it is connecting to an RVON 1 14 Press Enter 15 At the prompt type set channel 0 dest_chan 0 this tells the RVON I O it is connecting to channel 0 of the RVON 1 16 Press Enter 17 At the promp...

Страница 40: ......

Отзывы: