31
RVON-I/O Command Table
RVON-I/O A
port 1 set to 1 (set panel 0, poll ID 1)
port 2 set to 2 (set panel 1, poll ID 2)
RVON-I/O B
port 1 set to 3 (set panel 0, poll ID 3)
port 2 set to 4 (set panel 1, poll ID 4)
If you are using Cronus or AIO-16 with RVON-I/0 in Remote mode for keypanels, you will still have to set a panel poll ID.
This is because the RVON-I/O has a default panel poll ID of 0 (zero). This must be changed to a non-zero number.
NOTE
: Make sure to set the panel poll ID to 0 when trunking in Remote Mode. Doing this will ensure the RVON-I/O will not
respond to polls as a keypanel.
If the RVON-I/O in local mode is directly connected to a keypanel, the panel poll ID does not have to be set. The RVON-I/O
through polling will discover the address of the keypanel.
NOTE
: If you are getting audio, but cannot see the alphas on the keypanels, verify the set panel ID is set correctly.
If you connect an RVON-I/O in Local mode to an intercom serially, you must NOT connect the data lines.